Technical Alarm Messages (INOPs)
INOP Message, Indication
<SpO
2
Numeric is replaced by -?-
INOP tone
<SpO
2
Numeric unavailable
<SpO
2
Numeric is replaced by -?-
INOP tone.
<SpO
2
Numeric is replaced by -?-
INOP tone
<SpO
2
Numeric is replaced by a -?-
<SpO
2
Numeric is replaced by -?-
INOP tone
<SpO
2
Label is displayed with a -?-, numeric is
unavailable
Sp - vO
Numeric is replaced by -?-
Sp - vO
Numeric is replaced by -?-
SRR INTERFERENCE
INOP tone
SRR INVALID CHAN
INOP tone
SRR MALFUNCTION
SVR/SVRI CHK SOURCES
Numeric is replaced by -?-
SVR/SVRI CHK UNITS
Numeric is replaced by -?-
SVR/SVRI SET CVP USED
Numeric is replaced by -?-
T/T1/T2/T3/T4 INOPs
TAAP DISABLED
INOP tone
Tamb INOPs
Tart INOPs
LABEL> PULSE?
LABEL> SEARCHING
label> SENSOR MALF
LABEL> SENSOR OFF
LABEL> UNKN.SENSOR
LABEL> UNPLUGGED
LABEL> UPGRADE
CHK SOURCES
2
CHK UNITS
2
Source
What to do
SpO
The detectable pulsations of the SpO
2
specified pulse rate range.
SpO
SpO
is analyzing the patient signal to derive Pulse, SpO
2
2
Perf values. Please wait until the search analysis is complete.
SpO
The SpO
sensor or adapter cable is faulty. Try another adapter
2
2
cable and sensor. If the INOP persists, contact your service
personnel.
SpO
The SpO
sensor is not properly applied to the patient. Apply
2
2
the sensor following the instructions supplied by the
manufacturer.
SpO
The connected sensor or adapter cable is not supported by the
2
SpO
measurement. Use only specified sensors and cables.
2
SpO
An SpO
measurement label has been deactivated, either by
2
2
unplugging a module, or by deactivating the label in the
Measurement Selection window.
The measurement automatically disappears from the display.
To switch the measurement on again, either replug the module
or reactivate the measurement label in the Measurement
Selection window.
SpO
The SpO
measurement is currently in UPGRADE mode.
2
2
Monitoring is not possible in this mode.
Sp - vO
Not all measurements or values required to perform the
2
calculation are available. Check measurement sources.
Sp - vO
The monitor has detected a conflict in the units used for this
2
calculation. Check the unit settings.
Monitor
The short range radio connection has interference from
another device. Try using another channel.
Monitor
The channel configuration of the Short Range Radio is invalid.
Check channel and channel mask configuration.
Malfunction in the short range radio device. If the INOP
persists contact your service personnel.
SVR/SVRI
Not all measurements or values required to perform the
calculation are available. Check measurement sources.
SVR/SVRI
The monitor has detected a conflict in the units used for this
calculation. Check the unit settings.
SVR/SVRI
A CVP value is required for this calculation, but is not
currently being measured. The monitor is using the CVP value
preset in the
Setup SVR
TEMP
See <Temp label> INOPs (under Temp)
Monitor
The currently selected telemetry configuration on the monitor
does not allow connection of telemetry devices to the monitor.
TEMP
See <Temp label> INOPs (under Temp)
TEMP
See <Temp label> INOPs (under Temp)
5 Patient Alarms and INOPs
signal are outside the
2
menu.
and
2