Download  Print this page

Philips Expression MR400 Instructions For Use Manual Page 154

Mri patient monitoring system.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418

Advertisement

Patient Alarm
Violated secondary
agent Et value
Violated secondary
agent Fi value
Missing primary and
secondary agent data
Violated N2O value
Missing N2O data
Violated O2 value
Violated O2 value
Missing O2 data
Missing bellows
respiration rate data
Violated temperature
value
Missing temperature
data
Violated non-invasive
blood pressure systolic
value
4‐30  Alarms                                                                                                                                     Expression MR400 Instructions for Use
From
Condition
AGENT
The end-tidal measurement for the
secondary agent gas has violated
an alarm limit setting.
AGENT
The fractional inspired
measurement for the secondary
agent gas has violated an alarm
limit setting.
AGENT
The primary and secondary agent
data, once present, can no longer
be produced.
AGENT
The N2O measurement has
violated an alarm limit setting.
AGENT
The N2O data, once present, can
no longer be produced.
AGENT
The O2 measurement has violated
an alarm limit setting.
AGENT
The O2 measurement is less than
18 percent.
AGENT
The O2 data, once present, can no
longer be produced.
RESP
The bellows respiration data, once
present, can no longer be
produced.
TEMP
The temperature measurement
has violated an alarm limit setting.
TEMP
The temperature data, once
present, can no longer be
produced.
NIBP
The non-invasive blood pressure
systolic measurement has violated
an alarm limit setting.
Indication
Flashing yellow secondary agent Et numeric in
the AGENT VS box, yellow alarm light,
medium priority alarm tone, where OVR
displayed if the value is greater than the highest
specified
Flashing yellow secondary agent Fi numeric in
the AGENT VS box, yellow alarm light,
medium priority alarm tone, where OVR
displayed if the value is greater than the highest
specified
Flashing yellow dashes (- - -) in the primary and
secondary numerics in the AGENT VS box,
yellow alarm light, medium priority alarm tone
Flashing yellow N2O numeric in the GAS VS
box, yellow alarm light, medium priority alarm
tone
Flashing yellow dashes (- - -) in the N2O
numeric in the GAS VS box, yellow alarm light,
medium priority alarm tone
Flashing yellow O2 numeric in the GAS VS
box, yellow alarm light, medium priority alarm
tone
Flashing red O2 numeric in the GAS VS box,
red alarm light, high priority alarm tone
Flashing yellow dashes (- - -) in the O2 numeric
in the GAS VS box, yellow alarm light, medium
priority alarm tone
Flashing yellow dashes (- - -) in the respiration
rate numeric in the RESP VS box, yellow alarm
light, medium priority alarm tone
Flashing yellow temperature numeric in the
TEMP VS box, yellow alarm light, medium
priority alarm tone, where OVR displayed if
the value is greater than the highest specified
or UND if the value is less than the lowest
specified
Flashing yellow dashes (- - -) in the
temperature numeric in the TEMP VS box,
yellow alarm light, medium priority alarm tone,
where OVR displayed if the value is greater
than the highest specified or UND if the value
is less than the lowest specified
Flashing yellow systolic numeric in the NIBP VS
box, yellow alarm light, medium priority alarm
tone, where OVR displayed if the value is
greater than the highest specified or UND if
the value is less than the lowest specified

Advertisement

Chapters

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments: