Download  Print this page

Listing Of Alarms - Philips Expression MR400 Instructions For Use Manual

Mri patient monitoring system.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418

Advertisement

Vital Sign or
Parameter
SPO2
P1 and P2
P1 and P2
P1 and P2
P1 and P2
NIBP
NIBP
NIBP
NIBP
NIBP
NIBP
NIBP
NIBP
NIBP
Temperature
CO2 (LoFlo option)
CO2 (LoFlo option)
CO2 (LoFlo option)
CO2 (AGENT option)
CO2 (AGENT option)
CO2 (AGENT option)
AGENT
AGENT
AGENT
AGENT
AGENT
AGENT
AGENT
AGENT
Bellows Respiration

Listing of Alarms

This section lists patient alarms alphabetically, and technical alarms (INOPs) arranged by the 
source of the INOP and then alphabetically, irrespective of priority. All alarms and INOPs are 
listed here; those which can appear on your MR400 will depend on the installed options. 
4‐26  Alarms                                                                                                                                     Expression MR400 Instructions for Use
Numeric
Units
Item
Saturation
%
Systolic
mmHg
Mean
mmHg
Diastolic
mmHg
Pulse Rate
BPM
Systolic
mmHg
Systolic
mmHg
Systolic
mmHg
Mean
mmHg
Mean
mmHg
Mean
mmHg
Diastolic
mmHg
Diastolic
mmHg
Diastolic
mmHg
Temperature
°C
CO2 (Et)
mmHg
CO2 (Fi)
mmHg
Resp. Rate
RPM
CO2 (Et)
mmHg
CO2 (Fi)
mmHg
Resp. Rate
RPM
Desflurane (Et & Fi)
%
Enflurane (Et & Fi)
%
Halothane (Et & Fi)
%
Isoflurane (Et & Fi)
%
Sevoflurane (Et & Fi)
%
N2O (Et)
%
N2O (Fi)
%
O2 (Fi)
%
Resp. Rate
RPM
Measurement
Patient
Range
Type
Low
High
All
1
100
Adult
-30
250
Ped
-30
250
Neo
-30
250
All
30
250
Adult
30
270
Ped
30
180
Neo
30
130
Adult
20
255
Ped
20
160
Neo
20
120
Adult
10
245
Ped
10
150
Neo
10
100
All
20.0
44.0
All
0
All
0
All
4
100
All
0
All
0
All
4
100
All
0
18.0
All
0
All
0
All
0
All
0
All
0
100
All
0
100
All
0
100
All
4
150
Over / Under
Values
Under
Over
none
none
-30
250
-30
250
-30
250
30
250
30
270
30
180
30
130
20
255
20
160
20
120
10
245
10
150
10
100
20.0
44.0
90
none
90
90
none
90
none
100
90
none
90
90
none
90
4
100
none
18.0
5.0
none
5.0
5.0
none
5.0
5.0
none
5.0
8.0
none
8.0
none
none
none
none
none
none
4
150

Advertisement

Chapters

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments: