Download  Print this page

Measurement Limits And Over / Under Values - Philips Expression MR400 Instructions For Use Manual

Mri patient monitoring system.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418

Advertisement

Vital Sign or Parameter
NIBP Systolic
NIBP Mean
NIBP Diastolic
Temperature
DES (Et), Expired Desflurane
DES (Fi), Inspired Desflurane
ENF (Et) Expired Enflurane
ENF (Fi) Inspired Enflurane
HAL (Et) Expired Halothane
HAL (Fi) Inspired Halothane
ISO (Et) Expired Isoflurane
ISO (Fi) Inspired Isoflurane
SEV (Et) Expired Sevoflurane
SEV (Fi) Inspired Sevoflurane
N2O (Fi) Inspired Nitrous
Oxide
O2 (Fi) Inspired Oxygen
*For all alarm limit values that may be displayed in units of kPa, allow +/‐ 0.1 kPa of variance to account for rounding error that may 
occur when converting from mmHg to kPa.

Measurement Limits and Over / Under Values

In the table below, the range of values that can be measured for a vital sign item are provided 
along with the high and low values that, beyond which, an over or under indication will be given. 
Specifically, a value will be marked as Over (OVR) if the VS value is greater than the given over 
value, and marked as Under (UND) if the VS value is less than the given under value. 
Vital Sign or
Parameter
ECG
ECG
ECG
SPO2
Expression MR400 Instructions for Use                                                                                                                                    Alarms   4‐25
Adult
Unit
Low
Limit
mmHg
65
kPa
8.7
mmHg
55
kPa
7.3
mmHg
40
kPa
5.3
°C
36.0
°F
96.8
Vol. %
Off
Vol. %
Off
Vol. %
Off
Vol. %
Off
Vol. %
Off
Vol. %
Off
Vol. %
Off
Vol. %
Off
Vol. %
Off
Vol. %
Off
Percent
No low
alarm
Percent
18
Numeric
Units
Item
Heart Rate
BPM
Heart Rate
BPM
Heart Rate
BPM
Heart Rate
BPM
Pediatric
High
Low
Limit
Limit
190
70
25.3
9.3
135
50
18.0
6.7
125
40
16.7
5.3
39.0
36.0
102.2
96.8
12.0
Off
18.0
Off
3.4
Off
5.0
Off
1.5
Off
2.2
Off
2.3
Off
3.4
Off
4.1
Off
6.1
Off
No low
80
alarm
99
18
Measurement
Patient
Type
Low
Adult
30
Ped
30
Neo
30
All
30
Neo
High
Low
Limit
Limit
120
70
16.0
9.3
90
40
12.0
5.3
70
35
9.3
4.7
39.0
36.0
102.2
96.8
12.0
Off
18.0
Off
3.4
Off
5.0
Off
1.5
Off
2.2
Off
2.3
Off
3.4
Off
4.1
Off
6.1
Off
No low
80
alarm
99
18
Over / Under
Range
Values
High
Under
250
30
300
30
300
30
250
30
High
Limit
100
13.3
90
12.0
50
6.7
39.0
102.2
12.0
18.0
3.4
5.0
1.5
2.2
2.3
3.4
4.1
6.1
80
99
Over
250
300
300
250