Alarm Limit Factory Defaults - Philips Expression MR400 Instructions For Use Manual

Mri patient monitoring system.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418

Advertisement

Breath Phase and Gas
SEV (Et) Expired Sevoflurane
SEV (Fi) Inspired Sevoflurane
N2O (Fi) Inspired Nitrous
Oxide
O2 (Fi) Inspired Oxygen

Alarm Limit Factory Defaults

In the event of power loss, any alarm limit settings that were changed will be lost. All settings that 
may have been modified to suit a particular patient should be confirmed before monitoring. 
At power up, the MR400 will automatically set all alarm limits as determined by the default 
selected in the Edit User Settings menu; see page 3‐15. The factory default alarm limits are listed 
in the table below.
Note
You are restricted from making changes to the factory default settings.
Vital Sign or Parameter
Heart Rate
Heart Rate - Extreme
Bradycardia
Heart Rate - Extreme
Tachycardia
SPO2
SPO2 - Desat
CO2 (Et)
CO2 (Fi)
CO2 (Resp)
P1 / P2 Systolic
P1 / P2 Mean
P1 / P2 Diastolic
4‐24  Alarms                                                                                                                                     Expression MR400 Instructions for Use
Low Alarm Limit
Unit
Minimum
Vol. %
Off, 0.1
Vol. %
Off, 0.1
Percent
No low alarm
Percent
18
Adult
Unit
Low
Limit
BPM
45
BPM
20
BPM
20
Percent
85
Percent
80
mmHg
15
kPa
2.0
mmHg
No low
kPa
alarm
RPM
4
mmHg
65
kPa
8.7
mmHg
55
kPa
7.3
mmHg
40
kPa
5.3
High Alarm Limit
Maximum
Minimum
8.0
0.1
8.0
0.1
0
100
18
Pediatric
High
Low
Limit
Limit
160
75
20
20
20
20
Off
90
80
80
60
15
8.0
2.0
4
No low
0.5
alarm
40
4
190
70
25.3
9.3
135
50
18.0
6.7
125
40
16.7
5.3
Low and
High Limit
Maximum
Separation
8.0, Off
8.0, Off
80
100
Neo
High
Low
Limit
Limit
160
90
20
20
20
20
Off
90
80
80
60
30
8.0
4.0
4
No low
0.5
alarm
40
30
120
70
16.0
9.3
90
40
12.0
5.3
70
35
9.3
4.7
1
1
1
1
High
Limit
210
20
20
Off
80
45
6.0
4
0.5
70
100
13.3
90
12.0
50
6.7

Advertisement