DANA Diabecare II SR User Manual

Iisr insulin pump
Table of Contents

Advertisement

Quick Links

#다나2SR영문메뉴얼 rev.0 2007.7.3 5:43 PM 페이지1 001 Acrobat™ PDFWriter 300DPI 60LPI
DANA Diabecare
User Manual
IISR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Diabecare II SR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DANA Diabecare II SR

  • Page 1 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:43 PM 페이지1 001 Acrobat™ PDFWriter 300DPI 60LPI DANA Diabecare User Manual Ⓡ IISR...
  • Page 2 SOOIL Development Co., Ltd. has been committed to making scientific advancements in the development and production of innovative medical solutions for the management, treatment and cure of diabetes throughout the world since 1979. Your DANA Diabecare IISR has been designed and built with the most Ⓡ...
  • Page 3 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:43 PM 페이지3 001 Acrobat™ PDFWriter 300DPI 60LPI DANA Diabecare User Manual Ⓡ IISR...
  • Page 4: Table Of Contents

    3. Filling and inserting a new reservoir •Changing the reservoir - Preparation - Filling the reservoir with insulin - Instructions for use of DANA Easy SETTER - Inserting the reservoir into the pump - Connecting the infusion set to your pump - Priming the infusion set - Inserting the infusion set •Infusion sets...
  • Page 5 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:43 PM 페이지5 001 Acrobat™ PDFWriter 300DPI 60LPI - Soft-Release-ST •General Precautions for All Infusion Sets 4. Bolusing and temporary basal rates •B o l u s •Temporary basal 5. Remote Control •Synchronize the Remote Control with the Pump •B o l u s •Lock Setting •Setting the Clock...
  • Page 6: Before Using Your Dana Diabecare Iisr Insulin Pump, Infusion Set And Reservoir

    4. Use the pad of your finger to press the buttons. DO NOT use your fingernails or any sharp objects to press the buttons. 5. Avoid the following conditions for safe storage and transport of the DANA Diabecare I I S R : Ⓡ...
  • Page 7: Explanation Of "W A R N I N G " , "C A U T I O N " , And "N O T E " S Y M B O L S

    Contents of the Dana Diabecare IISR Insulin Pump Kit Ⓡ INSULIN PUMP REMOTE CONTROL RESERVOIR (6) INFUSION SETS (6) DANA EASY SETTER (1) LINKING SCREW (2) BATTERY (2) ADHESIVE TAPE ™ B E L T BATTERY KEY (2) LEATHER CASE (2)
  • Page 8 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:43 PM 페이지6 001 Acrobat™ PDFWriter 300DPI 60LPI Identification and Description of the DANA IISR The DANA Diabecare IISR insulin pump, infusion set and reservoir are intended for the continuous delivery of insulin for the Ⓡ management of diabetes mellitus. It is not intended for the delivery of blood or blood products.
  • Page 9: Infusion Sets

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지7 001 Acrobat™ PDFWriter 300DPI 60LPI 1. Before using your DANA Diabecare IISR insulin pump, infusion set and reservoir Ⓡ Infusion Sets Superline (90° ) E a s y R e l e a s e...
  • Page 10: Set-Up And Basic Functions

    ④SET/PROGRAM icon - Choose the fourth icon (sliding scale) to ② ④ set basal rates, preset bolus doses and set clock. The DANA Diabecare IISR LCD screen will automatically go blank after one minute to conserve battery power. N o t e Ⓡ...
  • Page 11: Inserting The Battery

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지9 001 Acrobat™ PDFWriter 300DPI 60LPI 2. Set-up and basic functions Inserting the Battery O - r i n g graphic ① Follow these steps 1) Open the battery compartment by inserting the battery key into the battery cap and turning counterclockwise. 2) Insert the battery with the positive end down into the pump.
  • Page 12: Setting Bolus Doses, Basal Rates And The Clock 1

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지10 001 Acrobat™ PDFWriter 300DPI 60LPI Setting bolus doses, basal rates and the clock 1) From the INITIAL DISPLAY screen, press any of the control buttons and the BASIC DISPLAY screen will appear. 2) In the BASIC DISPLAY screen, press three times consecutively to highlight the S E T / P R O G R A M icon in figure 1.
  • Page 13: Setting A Bolus 1

    2. 4) After setting all of your meal boluses press to store the meal the meal bolus settings in the DANA memory. Make sure to press after the bolus dose is set to save the setting.
  • Page 14 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지12 001 Acrobat™ PDFWriter 300DPI 60LPI 2. Setting a Bolus 1) From the BASIC DISPLAY screen, go to the SET/PROGRAM screen. In SET/PROGRAM press when bolus icon is highlighted (figure 1). The bolus setting screen will appear as shown in figure 2. (figure 1) ①...
  • Page 15 3) After basal rates are set, press to save the settings in the DANA memory. You may confirm your basal settings by using the C H E C K / R E V I E W menu option (see page 15).
  • Page 16: Setting The Clock 1

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지14 001 Acrobat™ PDFWriter 300DPI 60LPI Setting the Clock 1) From the BASIC DISPLAY, go to the SET/PROGRAM screen. Press to highlight the CLOCK icon and press (figure 1). The CLOCK SETTING screen will appear as shown in figure 2. (figure 1) 2) U s e to move between the year and month and date, as well...
  • Page 17: Checking Bolus Doses, Basal Rates And Reviewing Memory Data 1

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지15 001 Acrobat™ PDFWriter 300DPI 60LPI 2. Set-up and basic functions Checking Bolus Doses, Basal Rates and Reviewing Memory Data 1) In the BASIC DISPLAY screen press until the C H E C K / R E V I E W icon is highlighted as in figure 1.
  • Page 18: Bolus History

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지16 001 Acrobat™ PDFWriter 300DPI 60LPI 5) Use to review the Bolus History including date, BOLUS HISTORY 1: 1/4 13:00 - 4 . 5 time and amount delivered (figure 5). Press to review the 500 2: 1/4 07:30 - 5 .
  • Page 19: Suspending The Pump 1

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지17 001 Acrobat™ PDFWriter 300DPI 60LPI 2. Set-up and basic functions Suspending the pump 1) In the BASIC DISPLAYscreen press to highlight the CHECK/REVIEW icon. Then press (figure 1) 2) Press to highlight the S U S P E N Dicon (figure 2). Then press 선택...
  • Page 20: User Setting 1

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지18 001 Acrobat™ PDFWriter 300DPI 60LPI User Setting 1) Press the three buttons ( ) at once to enter the PIN code screen for USER SETTING from the initial screen. (figure 1) 2) Input the PIN code “4 3 2 1 ” by the use of a n d b u t t o n s .
  • Page 21 BG level by the DANA IISG pump. If the “NO CARBO M O D E ” was selected as “O n” , the pop-up window will not be activated after the checking BG level.
  • Page 22 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지20 001 Acrobat™ PDFWriter 300DPI 60LPI ⑦STRIP CHECK STRIP CHECK - This is the menu for check whether or not the glucose meter of DANA Diabecare IISG operates normally. 1. Insert the “Check Strip” into the Glucose Meter Port when the “Strip C h e c k ”...
  • Page 23: Filling And Inserting A New Reservoir

    2) Suspend the pump and remove the old infusion set. 3) Remove the old reservoir. 4) Place all materials on a clean dry surface. Materials: DANA Diabecare IISR Insulin Pump, fast acting insulin, reservoir, infusion set, DANA Easy SETTER, Ⓡ linking screw, alcohol swab, etc. 5) Wash your hands.
  • Page 24: Filling The Reservoir With Insulin

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지22 001 Acrobat™ PDFWriter 300DPI 60LPI Filling the reservoir with insulin 1) Remove the round cap at the end of the reservoir plunger and discard. A thin white reservoir cap will fall out of the plunger - keep this cap for later use (figure 1).
  • Page 25: Instructions For Use Of Dana Easy Setter

    The DANA Easy SETTER operates with the SOOIL 3.6V battery N o t e 2) Insert a syringe filled with insulin into the DANA Easy SETTER (figure 2). The end (hexagonal part) of the connecting screw should be N o t e placed into the hexagonal hole of DANA Easy SETTER.
  • Page 26: Priming The Infusion Set 2

    3. Use to adjust the amount of insulin (in cc’ s ) in the new reservoir placed in the DANA pump. Then press (figure 3) Remember to adjust this setting up or down to the amount you have actually placed in the reservoir.
  • Page 27 Make sure to prime when you use a new infusion set or remove air from the tubing. W a r n i n g The DANA Diabecare IISR insulin pump will allow 2 prime sequences every 12 hours (0:00 - 12:00, 12:00 - N o t e Ⓡ...
  • Page 28: Inserting The Infusion Set 2

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지26 001 Acrobat™ PDFWriter 300DPI 60LPI Inserting the infusion set Make sure to prime when you use a new infusion set or W a r n i n g remove air from the tubing. 1) Choose an insertion site on your abdomen at least 5 cm away from the navel (figure 1).
  • Page 29: Easyrelease

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지27 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Filling and inserting a new reservoir Infusion Sets The EasyRelease Infusion Set The EasyRelease Infusion Set is a stainless steel needle set. A needle is inserted at 90° into the skin. The adhesive of the EasyRelease allows the needle to be fixed firmly in place.
  • Page 30 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지28 001 Acrobat™ PDFWriter 300DPI 60LPI I n s t r u c t i o n s 1. Prior to Inserting the EasyRelease Infusion Set 1) Wash your hands before handling the infusion set. 2) Take out the EasyRelease Infusion Set from its package.
  • Page 31 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지29 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Filling and inserting a new reservoir 3. Disconnecting the EasyRelease Infusion Set 1) Place the pump in SUSPEND (see page 17). 2) Push the Collar forward and pull the Infusion Set Connector out of the Site Connector (figure 9).
  • Page 32: Easyrelease Ii 3

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지30 001 Acrobat™ PDFWriter 300DPI 60LPI The EasyRelease II Infusion Set The EasyRelease II Infusion Set is a stainless steel needle set. A needle is inserted at 90° into the skin. The adhesive of the EasyRelease II allows the needle to be fixed firmly in place.
  • Page 33 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지31 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Filling and inserting a new reservoir I n s t r u c t i o n s 1. Prior to Inserting the EasyRelease II Infusion Set 1) Wash your hands before handling the infusion set. 2) Take out the EasyRelease II Infusion Set from its package.
  • Page 34 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지32 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Disconnecting the EasyRelease II Infusion Set 1) Place the pump in SUSPEND (see page 17). 2) Grasp each side of the Infusion Set Connector, pressing gently on the Spring Clips. Pull the Infusion Set Connector out of the Site Connector (figure 11).
  • Page 35: Soft-Release-R 3

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지33 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Filling and inserting a new reservoir The Soft-Release-R Infusion Set The Soft-Release-R is a soft cannula infusion set and is inserted at a 90° angle. The needle is removed after insertion and only the cannula remains under the skin.
  • Page 36 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지34 001 Acrobat™ PDFWriter 300DPI 60LPI 1. Prior to Inserting the Soft-Release-R Infusion Set 1) Wash your hands before handling the infusion set. 2) Take out the Soft-Release-R Infusion Set from its package. Be careful not to touch the connector to any object that would breach its sterility.
  • Page 37 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지35 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Filling and inserting a new reservoir 3. Disconnecting the Soft-Release-R Infusion Set 1) Place the pump in SUSPEND (see page 17). 2) Grasp each side of the Infusion Set Connector, pressing gently on the Spring Clips.
  • Page 38: Soft-Release-St 3

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지36 001 Acrobat™ PDFWriter 300DPI 60LPI The Soft-Release-ST Infusion Set The Soft-Release-ST is a soft cannula infusion set. It may be inserted at any angle between 15° and 30° , depending on your body type, comfort and instructions from your healthcare professional. The needle is removed after insertion and only the cannula remains under the skin.
  • Page 39 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지37 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Filling and inserting a new reservoir 1. Prior to Inserting the Soft-Release-ST Infusion Set 1) Wash your hands before handling the infusion set. 2) Take out the Soft-Release-ST Infusion Set from its package. Be careful not to touch the connector to any object that would breach its s t e r i l i t y .
  • Page 40 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지38 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Disconnecting the Soft-Release-ST Infusion Set 1) Place the pump in SUSPEND (see page 17). 2) Grasp each side of the Infusion Set Connector, pressing gently on the Spring Clips. Pull the Infusion Set Connector out of the Site Connector (figure 11).
  • Page 41: General Precautions For All Infusion Sets 3

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지39 001 Acrobat™ PDFWriter 300DPI 60LPI 3. Filling and inserting a new reservoir General Precautions for All Infusion Sets 1. Change the reservoir and the infusion set regularly as recommended by your healthcare professional. Do not use either for longer than 72 hours.
  • Page 42: B O L U

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지40 001 Acrobat™ PDFWriter 300DPI 60LPI 4. Bolusing, temporary basal rates, calculating your bolus dosage and dose automation B o l u s When Extended Bolus is set to OFF -Delivering a Bolus 1) Press any button while in the INITIAL DISPLAY screen to bring up the BASIC DISPLAY screen.
  • Page 43 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지41 001 Acrobat™ PDFWriter 300DPI 60LPI 4. Bolusing, temporary basal rates, calculating your bolus dosage and dose automation 4) Press twice to begin delivery. The screen in figure 3 will appear and you will hear the motor run as the bolus is being delivered. Press once and the word “B O L U S ”...
  • Page 44 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지42 001 Acrobat™ PDFWriter 300DPI 60LPI - Extended Bolus 1) In the BASIC DISPLAY screen press until the BOLUS icon is highlighted as in figure 1. Then press (figure 1) 2) Use to highlight the middle icon and press (figure 2) 3) Use to toggle between BOLUS amount and BOLUS Period...
  • Page 45 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지43 001 Acrobat™ PDFWriter 300DPI 60LPI 4. Bolusing, temporary basal rates, calculating your bolus dosage and dose automation 2) Use to highlight the rightmost icon and press 3) Use to toggle between STEP BOLUS and EXTEND BOLUS (figure 2) and BOLUS Period and make the necessary adjustments with than press...
  • Page 46 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지44 001 Acrobat™ PDFWriter 300DPI 60LPI - Extended Bolus Status 1) In the BASIC DISPLAY screen press until the BOLUS icon is highlighted as in figure 1. Then press (figure 1) 2) The screen will show how much time has elapsed since the start of the Extended Bolus, how much time is left until the completion of the Extended Bolus, amount delivered so far, and amount left to be delivered.
  • Page 47 4. (figure 4) Insulin is delivered every four minutes when the Dana IISR utilizes the extended bolus feature. While in extended N o t e bolus mode, insulin delivery will be halted during the following four events:...
  • Page 48: Temporary Basal 4

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지46 001 Acrobat™ PDFWriter 300DPI 60LPI Temporary Basal When Utility is set to OFF -Programming Temporary Basal Rates 1) Press any button while in the INITIAL DISPLAY screen to bring up the BASIC DISPLAY screen. (figure 1) 2) In the BASIC DISPLAY screen press until the TEMPORARY...
  • Page 49 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지47 001 Acrobat™ PDFWriter 300DPI 60LPI 4. Bolusing, temporary basal rates, calculating your bolus dosage and dose automation 4) P r e s s after making the desired adjustments to commence temporary basal. Upon pressing you will be returned to the BASIC DISPLAY screen and a “v”...
  • Page 50 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지48 001 Acrobat™ PDFWriter 300DPI 60LPI When Utility is set to ON -UTILITY MENU screen 1) In the BASIC DISPLAY screen, use to highlight the Utility icon ( f i g u r e 1 ) (Computer).
  • Page 51 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지49 001 Acrobat™ PDFWriter 300DPI 60LPI 4. Bolusing, temporary basal rates, calculating your bolus dosage and dose automation 4) U s e to move between “Ideal Blood Glucose” , “C I R ” , and ①...
  • Page 52 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지50 001 Acrobat™ PDFWriter 300DPI 60LPI - Temporary basal 1) In the BASIC DISPLAY screen, use to highlight the UTIL icon. Then press (figure 1) 2) While in the UTILITY MENU screen, use to highlight the TEMPORARY BASAL ICON.
  • Page 53 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지51 001 Acrobat™ PDFWriter 300DPI 60LPI 4. Bolusing, temporary basal rates, calculating your bolus dosage and dose automation - Temporary Basal Cancellation 1) In the BASIC DISPLAY screen, use to highlight the UTIL icon (Computer) and press .
  • Page 54 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지52 001 Acrobat™ PDFWriter 300DPI 60LPI - Dose Automation 1) In the BASIC DISPLAY screen, use to highlight the UTIL icon and press (figure 1) 2) U s e to highlight the rightmost icon and press access the DOSE AUTOMATION screen.
  • Page 55: Remote Control

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지53 001 Acrobat™ PDFWriter 300DPI 60LPI 5. Remote Control 5. Remote Control Synchronize the Remote Control with the Pump 1) Select the menu of connect icon at the basic menus display to synchronize the remote control with the pump (figure 1). (figure 1) An icon with four antennas will be displayed on the remote control N o t e...
  • Page 56: Lock Setting

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지54 001 Acrobat™ PDFWriter 300DPI 60LPI 3) Press twice to begin delivery. The screen in figure 2 will appear and you will hear the motor run as the bolus is being delivered. (figure 2) Press once and the word “B O L U S ”...
  • Page 57: Setting The Clock 5

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지55 001 Acrobat™ PDFWriter 300DPI 60LPI 5. Remote Control Setting the Clock 1) From the BASIC DISPLAY, go to the SET/PROGRAM screen. Press to highlight the CLOCK icon and press (figure 1). The (figure 1) CLOCK SETTING screen will appear as shown in figure 2.
  • Page 58: Checking Your Blood Glucose Level 5

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지56 001 Acrobat™ PDFWriter 300DPI 60LPI Checking your blood glucose level 1) After washing your hands, insert a DANA blood glucose strip into the blood glucose meter test port (figure 1). (figure 1) 2) The STRIP CODE SETTING screen will appear as in figure 2. Set the STRIP CODE and press The STRIP CODE range is between 0 and 49.
  • Page 59: Calculating Your Bolus Dosage 5

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지57 001 Acrobat™ PDFWriter 300DPI 60LPI 5. Remote Control 6) A 5 second countdown will appear as in figure 6. Once the countdown concludes the BLOOD GLUCOSE TEST RESULT screen will appear (date, time, blood glucose level) as in figure 7. (figure 6) Calculating your bolus dosage 1) While in the BLOOD GLUCOSE TEST RESULT screen, press...
  • Page 60 You must eat your meal after the meal bolus has been delivered. W a r n i n g The DANA Diabecare IISG insulin pump will deliver an audio reminder 30 minutes after bolus delivery. To stop the N o t e...
  • Page 61: Glucose Meter Related Error Messages And Troubleshooting 5

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지59 001 Acrobat™ PDFWriter 300DPI 60LPI 5. Remote Control Glucose meter related error messages and troubleshooting Please refer to the following in the event of a measurement error. N o t e S C R E E N P R O B L E M CORRECTIVE ACTION Strip has been used more than once.
  • Page 62: Troubleshooting

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지60 001 Acrobat™ PDFWriter 300DPI 60LPI 6. Troubleshooting When hypoglycemia (low blood sugar) occurs What is hypoglycemia (low blood sugar)? Hypoglycemia occurs when the blood sugar level is low. Anyone using insulin should be familiar with the symptoms and treatment of hypoglycemia.
  • Page 63: When Hyperglycemia (High Blood Sugar) Occurs 6

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지61 001 Acrobat™ PDFWriter 300DPI 60LPI 6. Troubleshooting POSSIBLE CAUSE SUGGESTED RESPONSE Consult with your diabetes professional to make adjustments for increased physical Increased physical activity activity. You may choose to use or modify temporary basal rates or decrease meal boluses prior to activity.
  • Page 64 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지62 001 Acrobat™ PDFWriter 300DPI 60LPI What to do in case of high blood sugar: 1) Check your blood sugar level. 2) Check your pump for any problems. 3) If your blood sugar remains high, take an injection of fast-acting insulin and contact your diabetes professional. POSSIBLE CAUSE SUGGESTED RESPONSE Visually check display screen for remaining insulin and also visually check reservoir...
  • Page 65: Problem / Correction Action 6

    Pump does not function Contact technical support. following CT or MRI scan The DANA Diabecare IISR insulin pump will allow 2 prime sequences every 12 Ⓡ Pump will not prime hours (0:00 - 12:00, 12:00 - 24:00).
  • Page 66: List Of Alarms And Audible Signals

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지64 001 Acrobat™ PDFWriter 300DPI 60LPI 7. List of alarms and audible signals LOW RESERVOIR screen appears The low reservoir screen will appear when there are approximately 20 units remaining. The pump will alarm every 30 seconds. Make a visual confirmation of remaining insulin through the reservoir cavity window on the side of pump.
  • Page 67: Specifications, Symbols, Warranty

    Integrated Circuit Dual microprocessors for continuous cross checking Classification and compliance with standards •The DANA Diabecare IISR is classified as an internal powered equipment BF type under the standard of IEC 60601-1 Ⓡ (Medical Electrical Equipment, General Requirements for Safety).
  • Page 68: Universal Symbols 6

    #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지66 001 Acrobat™ PDFWriter 300DPI 60LPI Universal Symbols S Y M B O L D E F I N I T I O N Read instructions for use. Sterilized with ethylene oxide Manufacture date Lot number Expiration date (Use by date) CE Marking (SGS UK) Do not re-use...
  • Page 69: Warranty 6

    The warranty period shall not be extended from the original purchase. This limited warranty is valid only if the DANA Diabecare insulin pump is used in accordance with all of the manufacturer’...
  • Page 70 #다나2SR영문메뉴얼 rev.0 2007.7.3 5:44 PM 페이지68 001 Acrobat™ PDFWriter 300DPI 60LPI IU-E-21 rev.0 w w w . s o o i l . c o m...

Table of Contents