Configure Bfd For Physical Ports - Dell S4048–ON Configuration Manual

S-series 10gbe switches
Hide thumbs Also See for S4048–ON:
Table of Contents

Advertisement

Configure BFD for IS-IS
Configure BFD for BGP
Configure BFD for VRRP
Configuring Protocol Liveness
Troubleshooting BFD

Configure BFD for Physical Ports

Configuring BFD for physical ports is supported on the C-Series and E-Series platforms only.
BFD on physical ports is useful when you do not enable the routing protocol. Without BFD, if the remote system fails, the local
system does not remove the connected route until the first failed attempt to send a packet. When you enable BFD, the local system
removes the route as soon as it stops receiving periodic control packets from the remote system.
Configuring BFD for a physical port is a two-step process:
1.
Enable BFD globally.
2.
Establish a session with a next-hop neighbor.
Related Configuration Tasks
Viewing Physical Port Session
Disabling and Re-Enabling
Enabling BFD Globally
You must enable BFD globally on both routers.
For more information about enabling BFD globally, refer to
To enable the BFD globally, use the following command.
Enable BFD globally.
CONFIGURATION mode
bfd enable
Example of Verifying BFD is Enabled
To verify that BFD is enabled globally, use the show running bfd command.
The bold line shows that BFD is enabled.
R1(conf)#bfd ?
enable
protocol-liveness
R1(conf)#bfd enable
R1(conf)#do show running-config bfd
!
bfd enable
R1(conf)#
148
Bidirectional Forwarding Detection (BFD)
Parameters.
BFD.
Enable BFD protocol
Enable BFD protocol-liveness
Establishing a Session on Physical