3. SPECIFICATIONS
Buffer Memory
Address (16 hex)
Watchdog timeout action for the
first slave station (WATCHDOG
01DE
H
TIMEOUT ACTION)
First Slave Station Production
01DF
H
Inhibit Time
Setting for the second slave
01E0
to 01E7
H
H
station
01E8
to 01EF
Setting for the third slave station
H
H
01F0
to 01F7
Setting for the 4th slave station
H
H
01F8
to 01FF
Setting for the 5th slave station
H
H
0200
to 0207
Setting for the 6th slave station
H
H
0208
to 020F
Setting for the 7th slave station
H
H
0210
to 0217
Setting for the 8th slave station
H
H
0218
to 021F
Setting for the 9th slave station
H
H
0220
to 0227
Setting for the 10th slave station
H
H
0228
to 022F
Setting for the 11th slave station
H
H
0230
to 0237
Setting for the 12th slave station
H
H
0238
to 023F
Setting for the 13th slave station
H
H
0240
to 0247
Setting for the 14th slave station
H
H
0248
to 024F
Setting for the 15th slave station
H
H
0250
to 0257
Setting for the 16th slave station
H
H
0258
to 025F
Setting for the 17th slave station
H
H
0260
to 0267
Setting for the 18th slave station
H
H
0268
to 026F
Setting for the 19th slave station
H
H
0270
to 0277
Setting for the 20th slave station
H
H
0278
to 027F
Setting for the 21st slave station
H
H
Setting for the 22nd slave station Same as with the first slave station
0280
to 0287
H
H
0288
to 028F
Setting for the 23rd slave station
H
H
0290
to 0297
Setting for the 24th slave station
H
H
0298
to 029F
Setting for the 25th slave station
H
H
02A0
to 02A7
Setting for the 26th slave station
H
H
02A8
to 02AF
Setting for the 27th slave station
H
H
02B0
to 02B7
Setting for the 28th slave station
H
H
02B8
to 02BF
Setting for the 29th slave station
H
H
02C0
to 02C7
Setting for the 30th slave station
H
H
02C8
to 02CF
Setting for the 31st slave station
H
H
Setting for the 32nd slave station Same as with the first slave station
02D0
to 02D7
H
H
Item
Slave station watchdog timeout action
Set value = 0000
Set value = 0001
Set value = 0002
Set value = 0003
Sets the production inhibit time.
Setting = 0000
Setting ≠ 0000
The setting will vary depending on the connection type. Refer to Table 3.21 for
further details of the setting.
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Same as with the first slave station
Contents
(default value)
H
Equal to TIMEOUT below.
: TIMEOUT
H
Connection enters timeout status. Can only be reset by the
operator stopping and restarting communication.
: AUTO DELETE
H
Connection is automatically deleted. Communication stops and
automatically restarts. Outputs are cleared to 0.
: AUTO RESET
H
Communication is continued with the connection maintained.
Outputs are not cleared to 0.
(default) → 20 ms
H
→ The value (setting - 1) is the minimum transmission interval
H
(ms).