Download Print this page

Motorola MOTOTRBO XIR R8200 Installation Manual: Equipment Ventilation; Ac Input Power Requirements; Circuit Overloading; Equipment Mounting Methods

Professional digital two-way radio system repeater.
Hide thumbs

Advertisement

1-2
For equipment operating in an area which is not environmentally controlled and with the repeater(s)
cabinet mounted, airborne particle level must not exceed 90 µg/m³.
!
C a u t i o n
1.3

Equipment Ventilation

The repeater is equipped with a cooling fan that is used to provide forced convection cooling. When
planning the installation, observe the following ventilation guidelines:
• Customer-supplied cabinets must be equipped with ventilation slots or openings in the front (for
air entry) and back or side panels (for air to exit). If several repeaters are installed in a single
cabinet, ensure ventilation openings surrounding each repeater allow for adequate cooling.
• All cabinets must have a least 15 cm (6 inches) of open space between the air vents and any
wall or other objects.
• When multiple cabinets (each equipped with several repeaters) are installed in an enclosed
area, ensure appropriate ventilation and consider air conditioning or other climate control
equipment to satisfy the temperature requirements stated under Section
Temperature Range
1.4

AC Input Power Requirements

The repeater is equipped with a switching power supply, and this assembly operates from 100 – 240
V
at 47 – 63 Hz AC input power. A standard 3-prong line cord is supplied to connect the power
AC
supply to the AC source.
It is recommended that a standard 3-wire grounded electrical outlet be used as the AC source.
!
C a u t i o n
The outlet must be connected to an AC source capable of supplying a maximum of 280 W. For a
nominal 110/120 V
breaker rated at 15A. For a nominal 220/240 V
be protected by a circuit breaker rated at 10 A.
1.4.1

Circuit Overloading

Consideration should be given to the effects of overloading on overcurrent protection devices and
supply wiring. Appropriate consideration of equipment ratings should be used when addressing this
concern.
1.5

Equipment Mounting Methods

The MOTOTRBO Repeater may be mounted in a rack, bracket or cabinet (available as accessories).
February 2008
If the repeater is to be installed in an environment which is usually dusty, dirty,
or does not meet the air quality requirements, then the air used to cool the
repeater modules must be treated using appropriate filtering devices. Dust or
dirt accumulating on the internal circuit boards and modules is not easily
removed, and can cause such malfunctions as overheating and intermittent
electrical connections.
on page 1-1.
The equipment must be installed near an easily-accessible AC source.
input, the AC source must supply 5 A and should be protected by circuit
AC
Pre-Installation Considerations Equipment Ventilation
input, the AC source must supply 3 A and should
AC
1.2.1 Operating
6816814H01

Advertisement

   Also See for Motorola MOTOTRBO XIR R8200

   Related Manuals for Motorola MOTOTRBO XIR R8200

Comments to this Manuals

Symbols: 0
Latest comments:
  • Chitta Sarker May 29, 2018 11:15:
    Hello,
    I would like to get your help about DC Lead connector of MOTOTRBO XIR R8200 Repeater.