Depending on the basic unit used, you can choose from among the following control
functions:
Table 4- 8
Application selection
Control function
Overload relay
Direct starter (direct-on-line starter)
Reversing starter
Molded-case circuit breaker (MCCB)
Star-delta starter
Star-delta reversing starter
Dahlander
Dahlander reversing starter
Pole-changing starter
Pole-changing reversing starter
Solenoid valve
Positioner (1, 2, 3, 4, 5)
Soft starter
Soft starter with reversing contactor
SIMOCODE pro - Parameterize
Operating Manual, 04/2017, A5E40507630002A/RS-AA/001
Short Description
SIMOCODE pro responds like an
overload relay.
Switching motor on and off
Control of direction of rotation of motors
(forward, reverse)
Switches a circuit breaker on and off
(e.g. 3WL, 3VL)
To limit the starting current, SIMOCODE
pro initially starts a motor with a star-
connected stator winding and then
switches it to delta.
Star-delta starter with both directions of
rotation (forward, reverse)
Control of motors with only one stator
winding in two speed steps (fast, slow)
Dahlander starter with both directions of
rotation (forward, reverse)
Control of motors with two stator
windings in two speed steps (fast, slow)
Pole-changing starter with both
directions of rotation (forward, reverse)
Control of a solenoid valve
Activation of positioners or actuators.
Versions 1 to 5
Control of the 3RW soft starter
Control of the 3RW soft starter, including
an additional reversing contactor
4.2 Motor control
Further information
See "Overload relay" control function
(Page 72)
See "Direct starter" control function
(Page 74)
See "Reversing starter" control function
(Page 76)
See "Molded case circuit breaker
(MCCB)" control function (Page 79)
See "Star-delta starter" control function
(Page 82)
See "Star delta reversing starter" control
function (Page 86)
See "Dahlander" control function
(Page 90)
See "Dahlander reversing starter"
control function (Page 93)
See "Pole-changing starter" control
function (Page 97)
See "Pole-changing reversing starter"
control function (Page 100)
See "Solenoid valve" control function
(Page 104)
See "Positioner" control function
(Page 107)
See "Soft starter" control function
(Page 112)
See "Soft starter with reversing
contactor" control function (Page 115)
Parameters
67