ARKSCAN AS500 User Manual

Ez one shot wireless ring barcode scanner

Advertisement

Ez One Shot
WIRELESS
RING
BARCODE
SCANNER
USER'S
MANUAL
Version: 2017.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AS500 and is the answer not in the manual?

Questions and answers

Summary of Contents for ARKSCAN AS500

  • Page 1 Ez One Shot WIRELESS RING BARCODE SCANNER USER’S MANUAL Version: 2017.1...
  • Page 2: Table Of Contents

    CONTENTS PREFACE Table of Contents............LED & Beeper Indication..........Cloning Mode............How to set up the parameter........GENERAL SETTINGS (GROUP 1 - 12) Default, Abort, Check Version, Setup Code Read..Reading Mode, Button/Illumination Preference..8 Beep tone, Terminator..........Send Data Length, Preamble, Postamble....Accuracy Adjustment..........
  • Page 3: Led & Beeper Indication

    LED & BEEPER INDICATION Status Green LED Blue LED Red LED Beeper Successful Barcode 1 Flash 1 beep Scan Successful 2 Flashes 2 beeps Connection Reads Configuration 1 Flash 2 beeps Barcode Barcode 1 Flash 1 beep Scan in Memory Mode Wireless 3 beeps 3 Flashes...
  • Page 4: Cloning Mode

    CLONING MODE WHAT IS CLONING MODE? CLONING duplicates a scanners settings in other scanners. It can save time when a number of scanners must be programmed to the same settings. HOW SHOULD CLONING WORK? 1. Using this guide, make all the necessary settings for one wand. 2.
  • Page 5: Cloning Mode

    CLONING MODE EXAMPLE : 1. PROJECT ASSIGNMENTS: 1.1. Beep tone: BEEP LOW. 1.2. Capslock Mode: CAPSLOCK ON. 1.3. Reading Mode: CONTINUOUS AUTO OFF. 2. SETTING PROCEDURE: 2.1. Scan BEEP LOW (GROUP 3). 2.2. Scan CAPSLOCK ON (GROUP 12). 2.3. Scan CONTINUOUS MODE (GROUP2). 3.
  • Page 6: How To Set Up The Parameter

    HOW TO SET PARAMETERS How do you program a scanner with this user’s guide? 1. Use the scanner to scan at the bar code representing the function/ parameter you want to set. 2. When you hear two beeps, the new settings have been defined or updated permanently to the scanner.
  • Page 7: General Settings (Group 1 - 12)

    GROUP-1 GENERAL SETTINGS . A001$ DEFAULT *Reset to factory default . A007$ CHECK VERSION *Check firmware version . P023$ RESET/ ABORT *Abort multi-step configuration SETUP CODE ON SETUP CODE READ SETUP CODE OFF *Caution: Scanning SETUP CODE OFF will turn the scanner into unprogrammable state and the scanner will not react to any configuration barcode! .
  • Page 8: Reading Mode, Button/Illumination Preference

    GROUP-2 GENERAL SETTINGS - READING MODE, BUTTON/ILLUMINATION PREFERENCE READING MODE . F005$ LED is always on. The trigger does not function in Continuous Mode. CONTINUOUS MODE . F002$ The LED will turn on when the trigger is pressed. The LED will go off when the trigger is TRIGGER MODE released.
  • Page 9: Beep Tone, Terminator

    GROUP-3 GENERAL SETTINGS - BEEP TONE, TERMINATOR BEEP TONE .F019$ .F018$ BEEP HIGH BEEP MEDIUM .F022$ . F012$ BEEP LOW BEEP OFF TERMINATOR . D013$ . D010$ CR+LF . D014$ NONE . D011$ . D015$ . D012$ SPACE . D016$ NOTES: 1.
  • Page 10: Send Data Length, Preamble, Postamble

    GROUP-4 SEND DATA LENGTH, PREAMBLE & POSTAMBLE. SEND DATA LENGTH .D019$ SEND DATA LENGTH ON .D020$ SEND DATA LENGTH OFF PREAMBLE & POSTAMBLE ( PREFIX AND SUFFIX ) . A011$ CLEAR PRE/ POSTAMBLE . A012$ PREAMBLE (16) . A013$ POSTAMBLE (16) EXAMPLE: Set PREAMBLE String as “...
  • Page 11: Accuracy Adjustment

    GROUP-5 GENERAL SETTINGS - ACCURACY ADJUSTMENT . A010$ ACCURACY ADJUSTMENT Accuracy Adjustment assures a more reliable decoded output. Enabling the feature and setting a number from 1 to 9 subjects the decoded output a higher standard of accuracy. The higher the number, the greater the accuracy.
  • Page 12: Code Id, Inverse Barcode

    GROUP-6 GENERAL SETTINGS - CODE ID, INVERSE BARCODE ENABLE INVERSE BARCODE .D021$ DISABLE INVERSE BARCODE [READS POSITIVE BARCODE ONLY] .D022$ ENABLE INVERSE BARCODE [READS POSITIVE & NEGATIVE BARCODES] CODE ID / SYMBOLOGY ID .A008$ FACTORY ID ON .A014$ AIM ID ON .A015$ SET ID ON .A009$...
  • Page 13: Symbologies Code Identifier

    GROUP-7 GENERAL SETTINGS - SYMBOLOGIES CODE IDENTIFIER SYMBOLOGIES CODE ID IDENTIFIER AIM ID Factory AIM ID Factory Symbologies Symbologies (new) (new) EAN 128 MSI(MOD 10 / CDV & not send CD) Code 128 Code 32 EAN8(+2/+5 OFF) EAN8(+2 ON) Codabar EAN8(+5 ON) Codabar(ABC Codabar) Codabar(CDV &...
  • Page 14: 8~9 Set Code Id

    GROUP-8 GENERAL SETTINGS - SET CODE ID . P001$ EAN 13 Set ID . P002$ EAN 8 Set ID . P003$ UPC E Set ID . P004$ UPC A Set ID . P005$ Code 39 Set ID . P013$ Code 93 Set ID .
  • Page 15 GROUP-9 GENERAL SETTINGS - SET CODE ID . P014$ MSI Code Set ID . P015$ UK Plessey Set ID . P017$ Matrix 2 of 5 Set ID . P006$ Interleaved 2 of 5 Set ID . P018$ Industrial 2 of 5 Set ID .
  • Page 16: Inter-Block And Inter-Character Delay

    GROUP-10 GENERAL SETTINGS INTERBLOCK DELAY 10mS 50mS 100mS 200mS 500mS INTERCHARACTER DELAY 140uS 500uS 16mS...
  • Page 17: Keyboard Layout

    GROUP-11 GENERAL SETTINGS - KEYBOARD LAYOUT KEYBOARD LAYOUT . C009$ . C010$ JAPAN (106 key) . C025$ ENGLISH (USA) . C018$ CANADIAN (FRENCH) . C034$ ENGLISH (UK) . C012$ CANADIAN (TRADITIONAL) . C029$ FRENCH . C011$ NORWEGIAN . C026$ GERMAN .
  • Page 18: Caplock Mode, Numeric Key, Ht/Cr/Esc Conversion

    GROUP-12 GENERAL SETTINGS - CAPLOCK MODE, NUMERIC KEY, HT/CR/ESC CONVERSION . A005$ CAPITAL LOCK MODE CAPLOCK OFF . A004$ . A006$ CAPLOCK ON CAPLOCK FREE NOTE: 1. When barcode scanner is set to Caplock Free mode, no matter keyboard Capslock LED indicator is ON or OFF, output will be always the same as the Original barcode.
  • Page 19: Wireless Scanner Settings (Group 13-20)

    GROUP-13 WIRELESS SCANNER SETTINGS INTERFACE . E043$ BT HID Emulates a Bluetooth HID keyboard that transmits each barcode data to the host after decode. Wireless scanner operates in this mode right out of box. Please see next page (Group 14) for details. .
  • Page 20: Bt Hid - Getting Connected

    GROUP-14 WIRELESS SCANNER SETTINGS BT - HID GETTING CONNECTED 1. Scan [Disconnect] to delete previous pairing record. Alternatively, you may long-press the function button for 5 seconds until the the scanner emit two beeps. . E031$ *.E031$* Disconnect 2. Scan [BT - HID]; the scanner will emit two beeps. .
  • Page 21: Bt Hid - Smartphone/Tablet Touch Keyboard

    GROUP-15 WIRELESS SCANNER SETTINGS BT - HID SMARTPHONE/TABLET TOUCH KEYBOARD While connected with the scanner, the Touch Keyboard on the iOS device might disappear. To resolve this issue, please simply press the function button to toggle iOS Touch Keyboard. Function Button Android While connected with the scanner, the Touch Keyboard on the Android smartphone or tablet might disappear.
  • Page 22: Power Off Timeout

    GROUP-16 WIRELESS SCANNER SETTINGS POWER OFF TIMEOUT Variable Timeout . B030$ SET MINUTE (Range: 00 ~ 60) . B029$ SET SECOND (Range: 00 ~ 60) The timeout is 30 seconds by default, and is programmable to the second and minute, ranging from 10 seconds (00:10) to 60 minutes and 60 seconds (60:60) For example, to set the timeout as 5 minutes 30 seconds: 1.
  • Page 23: Memory Mode - Memory Mode, Delete Record

    GROUP-17 WIRELESS SCANNER SETTINGS MEMORY MODE . C035$ MEMORY MODE After scanning the above barcode, the scanner will be able to collect barcode data off-line. The barcode data will be stored in the format of: < Date >, < Time >, < Barcode Data > < CR > To retrieve stored data, please connect the scanner to the host with cable, access removable storage device “MiniScan”...
  • Page 24 GROUP-18 WIRELESS SCANNER SETTINGS MEMORY MODE DATA FORMAT . R011$ DATA FORMAT The default Data Format for Memory Mode is <Date>, <Time>, <Barcode Data> below are items and their setup codes: Code Item Code Item Date Barcode Data Time Example: To change Data Format to <Barcode Data>, <Date>, <Time>...
  • Page 25: Memory Mode - Data Format, Date & Time Setup. 24 19 Memory Mode - Date Format, Time Format

    GROUP-19 WIRELESS SCANNER SETTINGS MEMORY MODE DATE FORMAT . R008$ DATE FORMAT The default Date Format for Memory Mode is DD/MM/YYYY (Code = 09), below is full list of available formats and their setup codes: Code Format Code Format DD-MM-YYYY DD/MM/YYYY MM-DD-YYYY MM/DD/YYYY...
  • Page 26: Symbologies (Group 21 - 38) 20~22 Enable/Disable Barcode Symbology

    GROUP-20 ENABLE/ DISABLE SYMBOLOGIES ENABLE DISABLE . A002$ . A003$ ENABLE ALL CODE . K010$ DISABLE ALL CODE . K011$ CODE 32 . K001$ CODE 32 . K002$ CHINA POSTAL CODE CHINA POSTAL CODE . L010$ . L011$ UK PLESSEY CODE .
  • Page 27 GROUP-21 ENABLE/ DISABLE SYMBOLOGIES ENABLE DISABLE . H001$ . H002$ UPC-A . H007$ UPC-A . H008$ UPC-E . H019$ UPC-E . H020$ EAN-8 . H013$ EAN-8 . H014$ EAN-13 . L001$ EAN-13 . L002$ . G008$ . G009$ CODE 39 .
  • Page 28: China Postal Code (Toshiba Code)

    GROUP-22 ENABLE/DISABLE SYMBOLOGIES, CHINA POSTAL CODE ENABLE . N032$ DISABLE . N033$ GS1 Databar ENABLE GS1 Databar DISABLE . N038$ . N039$ GS1 Databar STACKED ENABLE . N010$ GS1 Databar STACKED DISABLE . N011$ GS1 Databar LIMITED ENABLE . N026$ GS1 Databar LIMITED DISABLE .
  • Page 29 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 30: Msi, Uk Plessey Code

    GROUP-23 SYMBOLOGIES: MSI CODE, UK PLESSEY CODE . L001$ . L008$ ENABLE CHECK DIGIT DOUBLE 11 . L002$ PLUS MOD 10 . L009$ DISABLE CHECK DIGIT SINGLE . L004$ MOD 10 . L005$ CDV & SEND CD MIN LENGTH [ 6 ] .
  • Page 31 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 32: Code 93, Telepen, Iata

    GROUP-24 SYMBOLOGIES: CODE 93, TELEPEN, IATA . G010$ CODE 93 . G012$ ENABLE . G011$ MIN LENGTH [ 6 ] . G013$ DISABLE MAX LENGTH [ 48 ] . L014$ TELEPEN . L020$ ENABLE TELEPEN TELEPEN ASCII . L015$ . L021$ DISABLE TELEPEN TELEPEN NUMBER .
  • Page 33 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 34: Interleaved 2 Of 5, Code 11

    GROUP-25 SYMBOLOGIES: INTERLEAVED 2 OF 5, CODE 11 . J001$ INTERLEAVED 2 OF 5 . J008$ ENABLE . J002$ First digit suppressed . J009$ DISABLE . J003$ Last digit suppressed . J014$ DISABLE CDV . J004$ NO suppressed . J006$ CDV &...
  • Page 35 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 36: Industrial 2 Of 5, Matrix 2 Of 5

    GROUP-26 SYMBOLOGIES: INDUSTRIAL 2 OF 5, MATRIX 2 OF 5 INDUSTRIAL 2 OF 5 . N001$ . N005$ ENABLE . N002$ CDV & NOT SEND CD DISABLE . N006$ . N003$ MIN LENGTH [ 6 ] DISABLE CDV . N007$ .
  • Page 37 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 38: Codabar

    GROUP-27 SYMBOLOGIES: CODABAR . I 001$ CODABAR ENABLE . I 007$ . I 002$ CDV & NOT SEND CD . I 008$ DISABLE . I 005$ MIN LENGTH [ 6 ] . I 009$ DISABLE CDV . I 006$ MAX LENGTH [ 48 ] CDV &...
  • Page 39 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 40: Abc-Codabar, Cx-Codabar

    GROUP-28 SYMBOLOGIES: ABC- CODABAR, CX- CODABAR . I 017$ ABC- CODABAR . I 039$ . I 018$ INSERT DATA- ON . I 036$ . I 035$ INSERT DATA- OFF SET INSERT DATA* The data can be any alphanumerics of FULL ASCII Table (GROUP 40-46) ABC-CODABAR (American Blood Commission).
  • Page 41: Codabar Coupling, Codabar Adjacent Required

    GROUP-29 SYMBOLOGIES: CODABAR COUPLING, ADJACENT REQUIRED CODABAR COUPLING . I 019$ . I 041$ . I 020$ INSERT DATA - ON . I 026$ . I 021$ INSERT DATA- OFF SET INSERT DATA* ABC-Codabar and CX-Codabar have certain rules regarding the Stop Character of first bar code and the stop character of second bar code while in conjunction, while Codabar- Coupling is enabled, the data from any two Codabar bar codes...
  • Page 42: Standard & Full Ascii Code 39, Code 32

    GROUP-30 SYMBOLOGIES: STANDARD & FULL ASCII CODE 39, CODE 32 STANDARD CODE 39 . G003$ & FULL ASCII 39 DISABLE CDV . G008$ . G004$ ENABLE . G009$ CDV & SEND CD . G005$ DISABLE . G001$ CDV & NOT SEND CD .
  • Page 43 APPENDIX FULL ASCII ( Code 39 ) NUMERIC TABLE SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters.
  • Page 44: Upc-E

    GROUP-31 SYMBOLOGIES FORMATTING: UPC-E . H007$ UPC-E ENABLE . H010$ . H008$ LEAD DIGIT NO SEND . H011$ DISABLE . H009$ CHECK DIGIT SEND LEAD DIGIT SEND . H012$ CHECK DIGIT NO SEND . H037$ ADD ON SUPPLEMENT +5 ON .
  • Page 45: Upc-E System Number

    GROUP-32 SYMBOLOGIES: UPC-E SYSTEM NUMBER . H064$ UPC-E0 E [ 0 ] OFF . H063$ E ( 0 ) ON . H065$ UPC-E1 E [ 1 ] ON . H066$ E ( 1 ) OFF NOTE: Most UPC bar codes lead with 0 number systems, for these bar codes use UPC E(0) selection.
  • Page 46: Upc-A

    GROUP-33 SYMBOLOGIES FORMATTING: UPC- A . H001$ UPC- A . H004$ ENABLE . H002$ LEAD DIGIT NO SEND . H005$ DISABLE . H003$ CHECK DIGIT SEND LEAD DIGIT SEND . H006$ CHECK DIGIT NO SEND . H068$ UPC-A EXPAND TO EAN-13 ENABLE .
  • Page 47: Ean-8

    GROUP-34 SYMBOLOGIES FORMATTING: EAN 8 . H019$ EAN-8 . H022$ ENABLE . H020$ LEAD DIGIT NO SEND . H023$ DISABLE . H021$ CHECK DIGIT SEND LEAD DIGIT SEND . H024$ CHECK DIGIT NO SEND . H029$ ADD ON SUPPLEMENT . H043$ + 5 ON .
  • Page 48: Ean-13, Isbn, Issn

    GROUP-35 SYMBOLOGIES FORMATTING: EAN13, ISBN, ISSN, ISMN . H013$ EAN-13 . H016$ ENABLE . H014$ LEAD DIGIT NO SEND . H017$ DISABLE . H015$ CHECK DIGIT SEND . H018$ LEAD DIGIT SEND CHECK DIGIT NO SEND . H025$ ADD ON SUPPLEMENT .
  • Page 49: Ean/Ucc-128, Code 128

    GROUP-36 SYMBOLOGIES: EAN/UCC-128, CODE 128 . M001$ EAN/ UCC-128 . M005$ ENABLE . M002$ FUNC 1 CHAR SEND . M006$ DISABLE . M003$ FUNC 1 CHAR NOT SEND . M007$ CODE ID ENABLE . M004$ DEFINE EAN 128 CODE ID DISABLE NOTES: DEFINE EAN 128 The first FNC1 character is translated to ]c1, and the second FNC1 character is translated to an ASCII <GS>...
  • Page 50: Gs1 Databar

    GROUP-37 GS1 DataBar, LIMITED, EXPANDED GS1 DataBar (RSS) - OMNI & STACKED . N032$ . N033$ GS1 DataBar ENABLE . N034$ GS1 DataBar DISABLE . N035$ GS1 DataBar CHECK DIGIT SEND . N036$ GS1 DataBar CHECK DIGIT NOT SEND . N037$ GS1 DataBar PREFIX SEND .
  • Page 51: Full Ascii Table(Code 39)

    GROUP-38 FULL ASCII TABLE ( CODE 39 ) CONTROL CODES...
  • Page 52 GROUP-39 FULL ASCII TABLE ( CODE 39 ) CONTROL CODES...
  • Page 53 GROUP-40 FULL ASCII TABLE ( CODE 39 ) SYMBOLS...
  • Page 54 GROUP-41 FULL ASCII TABLE ( CODE 39 ) SYMBOLS >...
  • Page 55 GROUP-42 FULL ASCII TABLE ( CODE 39 ) UPPER CASE ALPHABETS...
  • Page 56 GROUP-43 FULL ASCII TABLE ( CODE 39 ) UPPER CASE ALPHABETS...
  • Page 57 GROUP-44 FULL ASCII TABLE ( CODE 39 ) LOWER CASE ALPHABETS...
  • Page 58 GROUP-45 FULL ASCII TABLE ( CODE 39 ) LOWER CASE ALPHABETS...
  • Page 59: Full Ascii Table(Code 39)

    GROUP-46 FULL ASCII TABLE ( CODE 39 ) NUMBERS...
  • Page 60: 49 Function Key Table(Code 39)

    GROUP-47 FULL ASCII TABLE ( CODE 39 ) FUNCTION KEYS Home $T+D Enter (Numeric Key) $T+O...
  • Page 61 GROUP-48 FULL ASCII TABLE ( CODE 39 ) NAVIGATION KEYS Cursor Right Cursor Left Cursor Up Cursor Down Page Up Page Down Back Tab Enter $T%K...
  • Page 62 GROUP-49 FULL ASCII TABLE ( CODE 39 ) MODIFIER KEYS $T%M $T%L Alt (Left) break $T+F Alt (Left) make*1 $T+E Alt (Right) break $T%O Alt (Right) make $T%N Shift (Left) break $T+J Shift (Left) make *2 $T+I Shift (Right) break $T+L Shift (Right) make $T+K...
  • Page 63 APPENDIX 1 DEFAULT TABLE 1 GROUP PARAMETER DEFAULT Setup Code Function Code Conversion Reading Mode Trigger Mode Button Preference Both Buttons Illumination Preference Laser always ON, LED ON after 1 sec Beep Tone Medium CR (BT HID, USB HID) Terminator CR+LF (USB VCP) Send Data Length Postamble...
  • Page 64 APPENDIX 1 DEFAULT TABLE 2 GROUP PARAMETER DEFAULT Code 93 Enable/Disable Disable Min Length Max Length Telepen Enable/Disable Disable Number/ASCII ASCII IATA Enable/Disable Disable Check Digit Verification Disable CDV Min Length Max Length Interleaved 2 of 5 Enable/Disable Enable Check Digit Verification Disable CDV Suppressed No Suppressed...
  • Page 65: Appendix 1

    APPENDIX 1 DEFAULT TABLE 3 GROUP PARAMETER DEFAULT UPC-E Expand to UPC-A Disable UPC-A Enable/Disable Enable Check Digit Verification Send CD UPC-A Expand to EAN-13 Disable Add a Space Addenda Required EAN-8 Enable/Disable Enable Check Digit Verification Send CD Add a Space Addenda Required EAN-13 Enable/Disable...
  • Page 66: Appendix 2 Barcode Test Chart

    APPENDIX 2 BAR CODE TEST CHART NARROW WIDE CHAR.GAP DENSITY mm[mil] mm[mil] mm[mil] RATIO MEDIUM 0.25(10) 0.625(25) 0.25(10) 1/2.5 DENSITY MEDIUM DENSITY NW-7 [CODABAR] CODE-39 Interleaved 2of5...
  • Page 67 APPENDIX 2 BAR CODE TEST CHART NARROW WIDE CHAR.GAP DENSITY mm[mil] mm[mil] mm[mil] RATIO 0.33(13) 0.825(32.5) 0.33(13) 1/2.5 DENSITY LOW DENSITY...

Table of Contents