2
Numbering system of model
2-4. Accessories (options)
Classification
EEV Kit
(Distributor kit) :
Set 2 or
3 EEV
MCU Kit
(Mode change
unit kit) :
4, 6 Indoor unit
connection
Discharge Duct
Refnet Joint
Model
Standard for model name
MXD : Distributor kit
MXD-!K@#$
! : EEV Capacity (Double figures)
• 14(For 2.0kW~4.0kW Capa Indoor)
• 18(For 5.2kW~8.5kW Capa Indoor)
@ : Number of ! Capa EEV
# : EEV Capacity (Double figures)
• 14(For 2.0kW~4.0kW Capa Indoor)
• 18(For 5.2kW~8.5kW Capa Indoor)
$ : Version
MCU : Mode change unit kit
MCU-!@#$
! : Indoor unit connection
MCU-%^
• 4:4 indoor unit can be connected
• 6:6 indoor unit can be connected
@ : Indoor power supply type
# : Refrigerant type
$ : Language
% : EEV existence
• E(EEV existence)
• blank(EEV nonexistence)
^ : Version
MDF : Outdoor discharge duct
MDF-!@
! : Hole size (ø, cm, Double figures)
@ : Version
MXJ : Refnet joint
MXJ-Y!@#
Y : One packing for gas and liquid side
! : Inlet pipe diameter for gas side
(mm, Double figures)
@ : Inlet pipe diameter for liquid side
(mm, Double figures)
# : Version
- 8 -
Examples
G MXD-14K300A
(3EA of 14
Capa EEV)
G MXD-14K218A
(2EA of 14
Capa EEV,
1EA of 18
Capa EEV)
G MCU-4ECEV0
-MCU for indoor
4 connection,
220~240V/50Hz
power supply,
English,
EEV existence
G MCU-4ECE0
G MDF-45A
G MXJ-Y3112A
(MXJ-3112A: gas side +
MXJ-1206A : liquid side)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avmkh032ca0Avmkh040ca0Avmkc020ea0Avmkc020ca0Avmkh020ca0Avmkh026ea0 ... Show all

Table of Contents