Ii8 - Wilbur Curtis Company G4CBHS User Manual

G4 series high volume combo brewers
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
Installation
Leveling
WARNING: Use the leveling legs to level the
brewer only. Do not use them to adjust brewer
height. Do not extend them higher than necessary.
1
Position the brewer on the counter top. Level it left to
right and front to back by turning the bottom of the
legs.
Connect the Water Supply
2
Flush the water supply line prior to installation to
3
the back of the brewer. Leave the water supply valve
closed until the power is connected.
Connect the Brewer Wiring
Brewers Without A Cord Set Attached
WARNING: Turn off power to the junction box at
the circuit breaker panel before connecting the
power cable to the brewer.
4
Remove the screws that hold the front cover in place
and remove the cover.
5
Loosen the strain relief on the back of the brewer.
6
On dual voltage units being operated at 220 Volts
(nominal) disconnect the existing power cable from
the terminal block and remove.
7
Feed the 220 Volt power cable into the brewer.
8
On dual voltage units being operated at 220 Volts,
disconnect and cap the jumper wire between the "C"
and "N" terminals on the terminal block.
9
Connect the wires on the power cable to the terminal
block inside the brewer.
10 Tighten the strain relief and replace the front cover.
11 Connect the power cable wires to the terminals in the
junction box. See the ELECTRICAL SCHEMATIC for
the power supply requirements.