Fan And Fan Cage Replacement; Remove The Fan Cage Assembly - Lenovo ThinkSystem SR850 Maintenance Manual

Hide thumbs Also See for ThinkSystem SR850:
Table of Contents

Advertisement

1. Read the safety information and installation guidelines (see "Safety" on page iii and "Installation
Guidelines" on page 51).
2. Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
3. Watch the procedure. A video of this procedure is available from the following links:
• https://www.youtube.com/playlist?list=PLYV5R7hVcs-B2y7oAb54mfyuLrIusa_qE
• http://list.youku.com/albumlist/show/id_50483449
To install the CMOS battery, complete the following steps:
Step 1.
Follow any special handling and installation instructions that come with the replacement battery.
Step 2.
Face the positive (+) symbol to the center of the server; then, place the battery into the seat until it
clicks in place.
Figure 48. CMOS battery installation
After installing the CMOS battery, complete the following steps:
1. Reinstall the system board air baffle (see "Install the system board air baffle and the power interposer"
on page 118) or processor and memory expansion tray and expansion tray air baffle (see "Install the
processor and memory expansion tray " on page 111).
2. Reinstall the top cover (see "Install the top cover" on page 131).
3. Reconnect the power cords and any cables that you removed.
4. Install the server in the rack.
5. Power on the server and any peripheral devices.

Fan and fan cage replacement

Use this procedure to remove or install fan and fan cage assembly.

Remove the fan cage assembly

Use this procedure to remove the fan cage assembly.
S002
CAUTION:
.
Chapter 3
Hardware replacement procedures
61

Advertisement

Table of Contents
loading