CHAPTER 5: SETTINGS
Setting name
Description
Firmware Lock
Indicates if the device receives firmware
(via Lock Relay)
upgrades. If Enabled and the firmware
upgrade attempt is made, the device denies
the upgrade and displays an error message
that the lock is set. On each firmware upgrade,
this setting goes back to the default.
The Lock Relay setting blocks settings and
firmware updates.
Factory Service
When enabled, the device can go into factory
Mode
service mode. To enable, Supervisor
authentication is necessary.
Restore to Defaults Sets the device to factory defaults
Supervisor Role
When enabled, the Supervisor role is active. To
enable, Administrator authentication is
necessary. When disabled, the Supervisor role
is inactive. To disable, Supervisor
authentication is necessary.
RADIUS user names Ensures that RADIUS user names are not the
same as local/device role names
Password
Local/device roles except for Observer are
password-protected. All RADIUS users are
password-protected.
Table 5-5: Security alarm settings
Setting name
Description / Details
Failed
A threshold number indicating when an alarm
Authentications
is set off to indicate too many failed
authentication attempts
Firmware Lock
A value indicating if the device can receive a
firmware upgrade. If Enabled and a firmware
upgrade attempt is made, the device alarm
activates. If Disabled, the device alarm does not
activate. On each firmware upgrade this setting
goes back to the default.
Settings Lock
A value indicating if the device can accept any
settings changes. If Enabled and a settings
change attempt is made, the device alarm
activates. If Disabled, the device alarm does not
activate.
CyberSentry settings through the front panel
SETTINGS  PRODUCT SETUP  SECURITY
 SECURITY
C70 CAPACITOR BANK PROTECTION AND CONTROL SYSTEM – INSTRUCTION MANUAL
Minimum
Disabled
Disabled
No
Disabled
See RADIUS
server
documents
See the
Password
Requirements
section earlier
in this chapter
LOGIN:
None
 CHANGE LOCAL
 PASSWORDS
 SESSION
 SETTINGS
Maximum Default
Enabled
Enabled
Enabled
Disabled
Yes
No
Enabled
Enabled
See
RADIUS
server
document
s
See the
Change
following
Me1#
password
section for
requireme
nts
Min
Max
Default
0
99
3
(disabled)
Disabled
Enabled Enabled
Disabled
Enabled Enabled
Range: Administrator, Engineer, Supervisor,
Operator, Factory (for factory use only), None
See page 5-20
See page 5-21
PRODUCT SETUP
Units
Minimum
permission
-
Administrator
-
Supervisor
(Administrator
when Supervisor
is disabled)
-
Administrator
-
Administrator to
enable and
Supervisor to
disable
-
Administrator
Text
The specified
role and
Administrator,
except for
Supervisor,
where it is only
itself
Units
Minimum
permissions
-
Administrator
-
Administrator
-
Supervisor
(Administrator if
Supervisor has
been disabled)
5-19
5

Advertisement

Table of Contents
loading