Bandwidth-Reference (Is-Is View); Circuit-Cost - HP FlexNetwork 3600 v2 Series Command Reference Manual

Hide thumbs Also See for FlexNetwork 3600 v2 Series:
Table of Contents

Advertisement

bandwidth-reference (IS-IS view)

Syntax
bandwidth-reference value
undo bandwidth-reference
View
IS-IS view
Default level
2: System level
Parameters
value: Bandwidth reference value in Mbps, ranging from 1 to 2147483648.
Description
Use bandwidth-reference to set the bandwidth reference value for automatic link cost calculation.
Use undo bandwidth-reference to restore the default.
By default, the bandwidth reference value is 100 Mbps.
Related commands: auto-cost enable.
Examples
# Configure the bandwidth reference of IS-IS process 1 as 200 Mbps.
<Sysname> system-view
[Sysname] isis 1
[Sysname-isis-1] bandwidth-reference 200

circuit-cost

Syntax
circuit-cost value [ level-1 | level-2 ]
undo circuit-cost [ level-1 | level-2 ]
View
IS-IS view
Default level
2: System level
Parameters
value: Link cost value. The value range varies with cost styles.
For styles narrow, narrow-compatible and compatible, the cost value ranges from 0 to 63.
For styles wide and wide-compatible, the cost value ranges from 0 to 16777215. When the
cost value is 16777215, the neighbor TLV generated on the link is used only to carry relevant
information about TE.
level-1: Applies the link cost to Level-1.
level-2: Applies the link cost to Level-2.
Description
Use circuit-cost to set a global IS-IS link cost.
128