Mitsubishi Electric F930GOT-BWD-E User Manual page 196

Graphic operation terminal
Hide thumbs Also See for F930GOT-BWD-E:
Table of Contents

Advertisement

Graphic Operation Terminal F930GOT
Example of screen changeover by screen No. stored in memory:
An example of screen changeover by screen No. stored in memory is shown below.
In the example below, an abnormality occurs in the machine in the operation mode, an error
message is displayed, then the previous screen is displayed.
Screen No. 0
* MONITOR *
CYCLE
OPERATION
CONTINUOUS
OPERATION
"CYCLE
*Screen No. is not stored.
OPERATION" key
Screen No. 1
ONE CYCLE DRIVEN
Condition
Control
Bit Device
Input
Touch key
1
Not specified
No. 0
M10
Not
(Active when:
2
specified
On = a
contact)
When M10 in the PLC becomes ON, the screen is changed
over.
At this time, the screen No. is stored in the screen No. storage
memory inside the GOT.
Screen No. 10
ERROR
MOTOR CHECK
MENU
"
To screen No. 1 or 2
To screen
(which is stored in
No. 0
the memory)
Use the screen No. storage function when one screen has been specified among two or more
screens, and the screen that was displayed prior to the screen changeover is to be displayed
again.
l The mode can be selected on the mode selection screen shown on
the left.
Touch key
When the "CYCLE OPERATION" or "CONTINUOUS OPERATION"
No. 0
key is pressed, a corresponding screen is displayed.
Touch key
No. 1
1
Touch key No. 0 Not specified
2
Touch key No. 1
When the "
" key is
pressed, the screen
No. 0 is displayed.
[ Screen changeover ]
Screen No.
Screen No.
(Destination
(Destination
Screen)
Screen)
Not made
0
effective
Made
10
effective
lWhen the bit device M0 in the PLC becomes ON, the
screen is changed over.
lCheck the contents, and return to the previous screen.
Condition
Control
Input
Touch key
1
No. 0
"
Touch key
2
No. 1
Changeover of Display Screen (FX-PCS-DU/WIN-E) 10
Screen changeover setting for individual screen
Condition
Control Input
Bit Device
Not specified
"CONTINUOUS
OPERATION" key
Screen No. 2
CONTINUOUS DRIVEN
Condition
Control
Input
Touch key
1
No. 0
Not
2
specified
Screen No.
Save Current
(Destination
Bit Device
Screen)
Not
DU memory
specified
Not
Not made
specified
effective
Screen No.
Save Current
(Destination
Screen
Screen)
1
Not made effective
2
Not specified
*Screen No. is not stored.
When the "
pressed, the screen
No. 0 is displayed.
[ Screen changeover ]
Screen No.
(Destination
Bit Device
Screen)
Not specified
0
M10
(Active when:
10
On = a
contact)
Screen
The screen stored in
the screen No. storage
Not made
memory is displayed.
effective
Not made
effective
" key is
Screen No.
(Destination
Screen)
Not made
effective
Made
effective
10-14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents