Translation of the original operating instructions Safety Basic safety notes • Read through the operating instructions before commissioning the tool and follow the instructions they contain to the letter • Keep the operating instructions together with the tool for future reference •...
• Do not use the welding plate if tired or under the influence of alcohol, drugs or medications • Do not leave the welding plate unattended • Only replace damaged parts with original Geberit spare parts • Wear non-slip safety shoes • Tie up baggy or loose clothing •...
• Geberit KSS-200 for Geberit PE and Mains frequency 50 Hz Geberit Silent-db20 ø 32–200 mm • Geberit KSS-315 for Geberit PE ø 200–315 mm Power consumption 630 W Any other use or a use extending beyond this is Protection degree IP20 deemed to be improper.
230 V 120 V Geberit welding plate KSS-160/KSS-200: the red signal lamp lights up during the heat- up phase. Once the welding temperature has been reached (after approx. 8 minutes), the green signal lamp lights up.
Should repair be necessary, the complete welding plate must be sent for repair in a suitable transport container. Repair work may only be performed by authorized repair shops. The addresses of authorised repair shops can be requested from the Geberit sales companies or found on www.geberit.com.