Installation Requirements; Tools And Parts - Kenmore W11024189A Installation Instructions Manual

Downdraft range
Table of Contents

Advertisement

Available languages

Available languages

NOTE: Please follow the instructions for the appropriate type of range. If you have an electric range, the gas installation
instructions do not apply.
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools Needed
Tape measure
Phillips screwdriver
Flat-blade screwdriver
1/8" (3 mm) flat-blade
screwdriver
Level
Drill
Adjustable wrench
Slip joint pliers
Pipe wrench
15/16" (2.4 cm)
combination wrench
1/8" (3.2 mm) drill bit
(for wood floors)
Marker or pencil
5
/
" (14.0 cm) hole saw
1
2
(round ducting)
Saw for 3
1
/
" x 10" (8.3 cm
4
x 25.4 cm) (rectangle vent)
#2 square bit and driver
Parts Supplied
Check that all parts are included.
Propane/Natural gas conversion kit (dual fuel models only)
Blower mounting/venting template
Grease filter (packaged in place)
Oven racks (3)
Blower motor kit (under unit)
Blower cover kit (packed in cavity)
10-32 hex nuts (attached to terminal block) (3)
Direct wire lugs (3)
#12 x 1
5
/
" (4.1 cm) screws (2)
8
Anti-tip bracket (inside oven cavity)
Anti-tip bracket must be securely mounted to the back wall
or floor. Thickness of flooring may require longer screws
to anchor bracket to subfloor. Longer screws are available
from your local hardware store.
4

INSTALLATION REQUIREMENTS

Tools and Parts

Flashlight
Masking tape
Pipe-joint compound
resistant to natural and
Propane gases
3/16" (4.8 mm)
carbide-tipped masonry
drill bit (for concrete/
ceramic floors)
Noncorrosive leak-
detection solution
Sheet metal aluminum
tape
For Propane/Natural Gas
Conversions
1/2" (13 mm) combination
wrench
1/4" (6 mm) nut driver
9/32" (7 mm) nut driver
Parts Needed
Use an approved vent cap for proper performance. If an
alternate wall or roof cap is used, be certain the cap size is
not reduced and that it has a backdraft damper.
After determining your vent installation, one of the
following is needed:
5" (12.7 cm) Round surface wall cap damper:
Order Part Number A405.
6" (15.2 cm) Round surface wall cap damper:
Order Part Number A406.
NOTE: If using 6" (15.2 cm) round venting, you will need a
5" (12.7 cm) to 6" (15.2 cm) round vent transition.
3
1
/
" x 10" (8.3 cm x 25.4 cm) Surface wall cap damper:
4
Order Part Number A403.
To order, see the "Assistance or Service" section of the Use and
Care Guide:
Metal ducting
Vent clamp
Aluminum foil tape
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See the appropriate "Electrical
Requirements" and "Gas Supply Requirements" sections.
It is recommended that all electrical connections be made by
a licensed, qualified electrical installer.
Optional Parts
To purchase these or any other accessories, please reference
the "Accessories" section of the Use & Care Guide for contact
information.
Side Trim Kits:
5/8" (1.7 cm) Black - Order Part Number W10675026
5/8" (1.7 cm) Stainless Steel - Order Part
Number W10675028
1
/
" (2.9 cm) Black - Order Part Number W10731886
1
8
1
1
/
" (2.9 cm) Stainless Steel - Order Part
8
Number W10731887
Backsplash Kits:
High 6" (15.2 cm) Black - Order Part Number W10655449
High 6" (15.2 cm) Stainless Steel - Order Part
Number W10655450

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents