Kenwood DP-1100 B Service Manual page 148

Table of Contents

Advertisement

D P - 1 1 0 0 B II
5 - 2 - 5 Grounding of e a c h positional detection leaf s w i t c h
T h e respective g r o u n d i n g routes of (1) start limit, (2) c l o s e d
tray (loading) a n d (3) o p e n e d tray (eject) d e t e c t i o n leaf s w i t ­
c h e s are s h o w n in Fig. M 1 9 .
(1) Start limit detection leaf s w i t c h
Leaf switch
Pan head screw M 2 x 6 (13)
Mechanism chassis (803)
Screw D T 2 . 6 x 6 (3)
Toothed washer (801)
FG PCB (5)
Ground lead with lug
Cross-recessed bind screw M2.6 x 12 (11)
Spacer (12)
Start limit detection leaf switch (S003)
Screw DT 2 . 6 x 6 (3) -
Toothed washer (801)
152
5. MECHANISM OPERATION
(2) C l o s e d tray detection leaf s w i t c h
Leaf switch
Pan head screw M2 x 6 (B)
Clamper lever mounting plate (814)
Screw D T 2 . 6 X 6 (3)
Main c h a s s i s (28)
Closed tray detection switch (S001)
Cross-recessed bind screw M 2 . 6 x 12 (11)
Fig. M 1 9 G r o u n d line of positional detection leaf s w i t c h e s
(1) Start limit d e t e c t i o n leaf s w i t c h
(2) Closed tray d e t e c t i o n leaf s w i t c h
(3) O p e n e d tray d e t e c t i o n leaf s w i t c h
(3) O p e n e d tray detection leaf s w i t c h
-Pan head screw M 2 x 6 (13)
-Clamper lever mounting plate (814)
Mechanism chassis (803)
- FG PCB (5)
Opened tray detection switch (S002)
• Main chassis (28)
^Spacer (12)
Leaf switch
Pan head screw M 2 x 6 (13)

Hide quick links: