Installation and clamping method
■
Installation direction
■
Installation should be done so that the cable gland is oriented toward the stern.
Bolts, nuts and tightening torque to be used
■
■ Use stainless steel bolts for the scanner and uniformly tighten all of the bolts using
double nuts for each bolt so that the scanner will not become loose (Table 1-2-1).
■ Although the length of the bolt will differ according to the thickness of the mount
base, use a bolt long enough so that more than 4 millimeters of thread protrudes
beyond the double nuts after the double nuts have been tightened.
Table 1-3-6-1 Length of scanner mounting bolts and tightening torque
Thickness of Mount Base (mm)
3-15 mm
(Recommend)
Use of washer and corrosion-resistant measures
■
■ At the location where a bolt's head or nut comes in contact with the scanner chassis'
legs and the mount base, insert a plain washer which fits the bolt; and, at the location
where the nut comes in contact with the plain washer, insert a spring washer, and
then securely tighten the nuts .
■ To prevent corrosion due to the contacts between different metals, such as the
scanner chassis' legs, installation surface, bolts, nuts, etc., cover the bolt's head and
nuts with sealant .
Grounding and corrosion-resistant measures
■
■ Do not install the scanner in place where puddles are often formed.
Bolt
M8X30SUS (attachment)
Chapter 1 INSTALLATION
Torque (N-m)
20 N-m
19