Download  Print this page
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460

Advertisement

3 Patient Alarms and INOPs
INOP Message, Indication
INVALID LEADSET
LEADSET UNPLUGGED
NO ECG SOURCE
!!TELE DISCONNECT
!!!TELE DISCONNECT
INOP tone
Tele Sync Unsupp.
INOP tone
ProtocolWatch INOPs
INOP Message, Indication
PW In Conflict
PW: Check Settings
PW:Action Required
Calculated Values INOPs
INOP Message, Indication
Sp-vO₂ CHK SOURCES
Numeric is replaced by -?-
Sp-vO₂ CHK UNITS
Numeric is replaced by -?-
SVR CHK SOURCES
SVRI CHK SOURCES
Numeric is replaced by -?-
SVR CHK UNITS
SVRI CHK UNITS
Numeric is replaced by -?-
SVR SET CVP USED
SVRISET CVP USED
ΔSpO₂ CHK SOURCES
Numeric is replaced by -?-
ΔSpO₂ CHK UNITS
Numeric is replaced by -?-
ΔTemp CHK SOURCES
Numeric is replaced by -?-
ΔTemp CHK UNITS
Numeric is replaced by -?-
90
What to do
The leadset has been unplugged from the telemetry device.
A telemetry device is paired with the monitor but the Information Center is not detecting a valid ECG
signal from either of them.
Telemetry transceiver was disconnected or short range radio link was lost.
For cable connections; check Telemetry interface, cable connection and setup.
For short range radio connections: if the telemetry transceiver has not moved out-of-range, check for
interference sources close to the monitor (bluetooth devices, DECT phones, cellular phones,
microwaves, etc.). If this INOP persists, ask your service personnel to survey the interference sources.
The MMS in use does not support synchronization of ECG and SpO
and central station after a telemetry device has been paired. Use an MMS with revision E.0 or above.
What to do
There is a patient information mismatch which has not yet been resolved (>15 minutes).
Contact your service personnel. Settings could not be loaded or interpreted correctly
The protocol currently running requires a user response. Check which pop-up window is displayed and
provide the appropriate response.
What to do
Not all measurements or values required to perform the calculation are available. Check measurement
sources.
The monitor has detected a conflict in the units used for this calculation. Check the unit settings.
Not all measurements or values required to perform the calculation are available. Check measurement
sources.
The monitor has detected a conflict in the units used for this calculation. Check the unit settings.
A CVP value is required for this calculation, but is not currently being measured. The monitor is using
the CVP value preset in the Setup SVR menu.
Not all measurements or values required to perform the calculation are available. Check measurement
sources.
The monitor has detected a conflict in the units used for this calculation. Check the unit settings.
Not all measurements or values required to perform the calculation are available. Check measurement
sources.
The monitor has detected a conflict in the units used for this calculation. Check the unit settings.
settings between the monitor