Download  Print this page
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460

Advertisement

Alarm Message
*** EXTREME BRADY
** HR LOW
* IRREGULAR HR
** IRREGULAR HR
* MISSED BEAT
** MISSED BEAT
* MULTIFORM PVCs
** MULTIFORM PVCs
** NBP HIGH
** NBP LOW
* NON-SUSTAIN VT
** NON-SUSTAIN VT
* PACER NOT CAPT
** PACER NOT CAPT
* PACER NT PACING
** PACER NT PACING
* PAIR PVCs
** PAIR PVCs
* PAUSE
** PAUSE
*** <Press Label> HIGH PRESS
** <Press Label> HIGH PRESS
From
Condition
ECG
The bradycardia limit has been exceeded.
ECG
The heart rate has fallen below the low alarm
limit.
ECG/Arrhythmia
Consistently irregular heart rhythm.
ECG/Arrhythmia
No beat detected for 1.75*R-R interval, or if
HR>120bpm no beat detected for one second
(non-paced patients only).
ECG/Arrhythmia
Two differently shaped Vs detected, each
occurring at least twice within the last 300 beats
and at least once within the last 60 beats.
NBP
The measured NBP value is above the high
alarm limit.
s, d, or m after the label indicates whether the
systolic, diastolic or mean pressure has crossed
the limit.
NBP
The measured NBP value is below the low
alarm limit.
s, d, or m after the label indicates whether the
systolic, diastolic or mean pressure has crossed
the limit.
ECG/Arrhythmia
A run of Vs having a ventricular HR>V-Tach
HR limit, but lasting for less than the V-Tach
Run limit has been detected.
ECG/Arrhythmia
A missed beat with a pace pulse was detected.
(paced patients
only)
ECG/Arrhythmia
A missed beat without a pace pulse was
(paced patients
detected.
only)
ECG/Arrhythmia
A non-ventricular contraction, followed by two
ventricular contractions, followed by a non-
ventricular contraction has been detected.
ECG/Arrhythmia
No beat detected for a period greater than the
pause threshold.
The measured pressure value is above the
extreme high alarm limit.
s, d, or m after the label indicates whether the
systolic, diastolic or mean pressure has crossed
the limit.
The measured pressure value is above the high
alarm limit.
s, d, or m after the label indicates whether the
systolic, diastolic or mean pressure has crossed
the limit.
3 Patient Alarms and INOPs
Indication
numeric flashes and alarm limit is
highlighted, red alarm lamp, alarm
tone
numeric flashes and low limit is
highlighted, yellow alarm lamp,
alarm tone. If configured to short
yellow, the sound switches off after
5 seconds if Arrhythmia is switched
on.
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes and high limit is
highlighted, yellow alarm lamp,
alarm tone
numeric flashes and low limit is
highlighted, yellow alarm lamp,
alarm tone
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes, yellow alarm lamp,
short yellow audible alarm
numeric flashes, high limit is
highlighted, red alarm lamp, alarm
tone
numeric flashes, high limit is
highlighted, yellow alarm lamp,
alarm tone
65

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments: