Download  Print this page
   
1
2
Table of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460

Advertisement

ECG/Arrhythmia/ST Performance Specifications
Sinus and SV Rhythm Ranges
Bandwidth
Bandwidth
when the ECG is transmitted from
a telemetry device via short range
radio
Differential Input Impedance
Common Mode Rejection Ratio
Electrode Offset Potential Tolerance
Auxiliary Current
(Leads off Detection)
Input Signal Range
ECG/Arrhythmia/ST/QT
Alarm Specifications
HR
Extreme Tachy
Extreme Brady
Run PVCs
PVCs Rate
Vent Tach HR
Vent Tach Run
Brady
Adult: 15 to 59 bpm
Pedi: 15 to 79 bpm
Neo: 15 to 89 bpm
Normal
Adult: 60 to 100 bpm
Pedi: 80 to 160 bpm
Neo: 90 to 180 bpm
Tachy
Adult: >100 bpm
Pedi: >160 bpm
Neo: >180 bpm
Diagnostic Mode
Adult/neo/pedi: 0.05 to 150 Hz
Extended Monitoring
Adult/neo/pedi: 0.5 to 150 Hz
Mode
Monitoring Mode
Adult: 0.5 to 40 Hz
Neo/pedi: 0.5 to 55 Hz
Filter Mode
Adult/neo/pedi: 0.5 to 20 Hz
Diagnostic Mode
Adult/neo/pedi: 0.05 to 40 Hz
Extended Monitoring
Adult/neo/pedi: 0.5 to 40 Hz
Mode
Monitoring Mode
Adult: 0.5 to 40 Hz
Neo/pedi: 0.5 to 40 Hz
Filter Mode
Adult/neo/pedi: 0.5 to 20 Hz
>2 MΩ RA-LL leads (Resp)
>5 MΩ at all other leads (at 10 Hz including patient
cable)
Diagnostic mode: >86 dB (with a 51 kΩ/47 nF
imbalance).
Filter mode: >106 dB (with a 51 kΩ/47 nF imbalance).
±500 mV
Active electrode: <100 nA
Reference electrode: <900 nA
±5 mV
Range
15 to 300 bpm
maximum delay: 10 seconds according
to AAMI EC 13-1992 standard
Difference to high limit 0 to 50 bpm
Clamping at 150 to 300 bpm
Difference to low limit 0 to 50 bpm
Clamping at 15 to 100 bpm
2 PVCs
1 to 99 PVCs/minute
20 to 300 bpm
3 to 99 PVCs/minute
36 Specifications
Adjustment
Adult:1 bpm steps (15 to 40 bpm)
5 bpm steps (40 to 300 bpm)
Pedi/Neo:1 bpm steps (15 to 50 bpm)
5 bpm steps (50 to 300 bpm)
5 bpm steps
5 bpm steps
5 bpm steps
5 bpm steps
Not adjustable by user
1 PVC
5 bpm
1 PVC