Routing Ffcs/Cables - Epson L365 Service Manual

Color inkjet printer
Hide thumbs Also See for L365:
Table of Contents

Advertisement

L365/L366,L360/L362,L310/L312,L220/L222,L130/L132 Series

2.4 Routing FFCs/cables

Route Scanner
PF Motor cable
FFC through Hole
of Housing Left.
Housing Left
Connect the following cables/FFCs to the Main Board as shown in the figure above.
PF Motor cable (CN13)
Panel FFC (CN2: L365/L366,L360/L362,L220/L222 Series only)
Scanner FFC (CN11: L365/L366,L360/L362,L220/L222 Series only)
Attach the ferrite core to the FFC Holder MB, and route the FFC through the hole of the Housing Left and the ferrite core, and then connect it to the Main Board.
Right side of Main Board
Head FFC
CN102
CN61
Main Board
CR Encoder FFC
CN12
CR Motor cable
Connect the following cables/FFCs to the Main Board as shown in the figure
above.
CR Motor cable (CN12)
CR Encoder FFC (CN61)
Head FFC (CN102)
Disassembly/Reassembly
Left side of Main Board
Ferrite core
FFC Holder MB
CN13
PS Unit cable
PF Encoder FFC
• PS Unit cable (CN501)
• Wireless LAN Module cable (CN4: L365/L366 Series only)
PF Encoder Sensor
Left side of printer
Rib
Ribs
CN7
Route the PF Encoder FFC through the ribs (x2) of the Main Frame and
connect it to the connector (CN7) on the Main Board, and then secure it with
double-sided tape (x2) on the positions shown in the figure above.
CN11
CN2
CN501
CN7
Panel Housing Lower Assy
Route the Panel FFC through the hole of the Panel Housing Lower Assy with its terminal side upward as shown in the figure above.
• PF Encoder FFC (CN7)
Fold the Panel FFC aligning it with its folded lines, and then connect the FFC to the connector (CN1) on the Panel Board firmly.
Note: This product does not have any panel grounding wire. The above figure includes a grounding wire because an XP-400 Series photo is used, however, there is no difference
in this procedure.
Panel Unit (1) (
L365/L366,L360/L362,L220/L222 Series
Panel Stand
PF Encoder Sensor
PF Encoder FFC
Route the Panel FFC as follows before installing the Panel Unit.
Route the Panel FFC through the hole of the Frame Base as shown
above with the side with the stiffener upward.
Before installing the Panel Unit, make sure that the Panel FFC is routed
Double Side Tape
correctly without any part getting caught.
Note: This product does not have any panel grounding wire. The above figure includes
a grounding wire because an XP-400 Series photo is used, however, there is no
difference in this procedure.
Routing FFCs/cables
Inside the Panel Unit (L365/L366,L360/L362,L220/L222 Series)
Panel Board
Panel FFC
)
Panel Unit (2) (
Hole for
Panel FFC
Panel FFC
Panel FFC
Frame Base
Panel FFC
Hole
After installing the Panel Unit, route the Panel FFC pulled out from the hole of
the Frame Base as follows.
Route Panel FFC through the ribs (x2) of the Frame Base and Main Frame
with folded along the fold line, and then secure it with double-sided tape
on the position shown in the figure above.
Note: This product does not have any panel grounding wire. The above figure includes
a grounding wire because an XP-400 Series photo is used, however, there is no
difference in this procedure.
Revision A
Hole of Panel Housing Lower Assy
Panel FFC
C.B.P-TITE SCREW 3x10 F/ZN-3C (6 ± 1 kgf·cm)
L365/L366,L360/L362,L220/L222 Series
)
Panel FFC
Panel Unit
Frame Base
Double-sided tape
Rib
50
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L360L366L310L312L313L220 ... Show all

Table of Contents