Check Fault - Eastwood VERSA CUT60 User Manual

Table of Contents

Advertisement

CHECK FAULT

Notes: If user wants to operate machine as following, the operator must be a
personnel in a specific field of electricity and safety and hold the relevant certificate
that proves their ability and knowledge. Before maintenance, contacting with our company
for authorization is suggested.
Faults
Meter can not display.
Fan can not run
Meter is normal,
Fan is normal
Cutting gun switch can
not work
Abnormal indicator is lit.
Meter is normal,
Fan is normal
Meter is normal,
Fan is normal,
Electromagnetic valve is
abnormal,
No arc output
Abnormal indicator is not
lit
Air switch can not close
If after checking and adjustment it still can not work normally, please contact the local
distributor or our service center.
Resolvable methods
1、Make sure air switch is on.
2、Power source of input cable has electricity.
3、Make sure power source not lack of phase.
1、Check if cable is loosen.
2、Control wire of gun broken or switch broken.
3、Control circuit is broken.(Contact factory)
1、High-pressure device is broken.
2、IGBT is broken.
3、Rectifier broken.
4、Control board is broken.
5、Feeding circuit broken(abnormal indicator lit), contact
factory.
1、Arcing part has problem.
2、Electricity-releasing nozzle is too far away.
3、High-pressure device is broken.
4、Relay is broken.
5、Control circuit broken.
1、Air switch quality is poor.
2、Three phase rectifying bridge is broken.
3、Check if any short circuit inside.