Appendix B: Reference Tables - GE Advent Installation Instructions Manual

Commercial fire system
Table of Contents

Advertisement

Appendix B: Reference Tables

This appendix contains tables for selecting zone type num-
bers, system features, X10 Module house, unit codes and
responses, SuperBus device unique ID numbers, and text
No.
Name
Application
00
Fixed Panic 24-hour audible fixed emergency
buttons.
01
Portable
24-hour audible portable
Panic
emergency buttons.
02
Fixed Panic 24-hour silent fixed emergency
buttons.
03
Portable
24-hour silent portable emergency
Panic
buttons.
04
Fixed
24-hour auxiliary sensor, such as
Auxiliary
Pendant Panic or holdup button.
05
Fixed
24-hour auxiliary emergency
Auxiliary
buttons. Siren shut-off confirms
CS alarm report.
06
Portable
24-hour portable auxiliary alert
Auxiliary
buttons.
07
Portable
24-hour portable auxiliary button.
Auxiliary
Siren shut-off confirms CS alarm
report.
08
Special
Special belongings, such as gun
Intrusion
cabinets and wall safes.
09
Special
Special belongings, such as gun
Intrusion
cabinets and wall safes.
10
Entry/Exit
Entry and exit doors that require a
Delay
standard delay time.
11
Entry/Exit
Garage doors and entrances that
Delay
require an extended delay time. *
12
Entry/Exit
Driveway gates and entrances that
Delay
require a twice extended delay
time. *
13
Instant
Exterior doors and windows.
Perimeter
14
Instant
Interior doors.
Interior
15
Instant
Interior PIR motion sensors. *
Interior
16
Instant
Interior doors.
Interior
17
Instant
PIR motion sensors. *
Interior
18
Cross Zone
PIR motion sensors subject to false
Instant
alarms. * †
Interior
19
Delayed
Interior doors that initiate a delay
Interior
before going into alarm.*
Advent Commercial Fire System
descriptor numbers. Table notes (if any) appear at the bot-
tom of the last page of the table.
Table B.1 Zone Type Characteristics
1, 2, 3, 4, 5 Police/Police
1, 2, 3, 4, 5 Police/Police
1, 2, 3, 4, 5 Police/Silent
1, 2, 3, 4, 5 Police/Silent
1, 2, 3, 4, 5 Aux./Aux.
1, 2, 3, 4, 5 Aux./Aux.
1, 2, 3, 4, 5 Aux./Aux.
1, 2, 3, 4, 5 Aux./Aux.
1, 2, 3, 4, 5 Police/Police
1, 2, 3, 4, 5 Police/Police
2, 3, 4, 5
Police/Police
2, 3, 4, 5
Police/Police
2, 3, 4, 5
Police/Police
2, 3, 4, 5
Police/Police
2, 3, 4, 5
Police/Police
2, 3, 4, 5
Police/Police
3, 4, 5
Police/Police
3, 4, 5
Police/Police
3, 4, 5
Police/Police
3, 4, 5
Police/Police
Note
Fire zone types are always active.
Instant
Instant
Instant
Instant
Instant
Instant
Instant
Instant
Instant
Standard
Standard
Extended
Twice
Extended
Instant
Follower
Follower
Follower
Follower
Follower
Standard
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents