B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 33 of 34)
ADDR
REGISTER NAME
E124
...Repeated for module number 10
E128
...Repeated for module number 11
E12C
...Repeated for module number 12
E130
...Repeated for module number 13
E134
...Repeated for module number 14
B
E138
...Repeated for module number 15
E13C
...Repeated for module number 16
E140
...Repeated for module number 17
E144
...Repeated for module number 18
E148
...Repeated for module number 19
E14C
...Repeated for module number 20
E150
...Repeated for module number 21
E154
...Repeated for module number 22
E158
...Repeated for module number 23
E15C
...Repeated for module number 24
E160
...Repeated for module number 25
E164
...Repeated for module number 26
E168
...Repeated for module number 27
E16C
...Repeated for module number 28
E170
...Repeated for module number 29
E174
...Repeated for module number 30
E178
...Repeated for module number 31
E17C
...Repeated for module number 32
Remote Output DNA Pairs (Read/Write Setting) (32 modules)
E600
Remote Output DNA x Operand
E601
Remote Output DNA x Events
E602
Remote Output DNA x Reserved (2 items)
E604
...Repeated for module number 2
E608
...Repeated for module number 3
E60C
...Repeated for module number 4
E610
...Repeated for module number 5
E614
...Repeated for module number 6
E618
...Repeated for module number 7
E61C
...Repeated for module number 8
E620
...Repeated for module number 9
E624
...Repeated for module number 10
E628
...Repeated for module number 11
E62C
...Repeated for module number 12
E630
...Repeated for module number 13
E634
...Repeated for module number 14
E638
...Repeated for module number 15
E63C
...Repeated for module number 16
E640
...Repeated for module number 17
E644
...Repeated for module number 18
E648
...Repeated for module number 19
E64C
...Repeated for module number 20
E650
...Repeated for module number 21
E654
...Repeated for module number 22
E658
...Repeated for module number 23
E65C
...Repeated for module number 24
E660
...Repeated for module number 25
E664
...Repeated for module number 26
E668
...Repeated for module number 27
E66C
...Repeated for module number 28
B-40
RANGE
0 to 65535
0 to 1
0 to 1
T60 Transformer Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F001
DEFAULT
0
0 (Disabled)
0
GE Multilin