5 SETTINGS
Table 5–7: T60 FLEXLOGIC™ OPERANDS (Sheet 3 of 4)
OPERAND TYPE
OPERAND SYNTAX
ELEMENT:
SELECTOR 1 POS Y
Selector Switch
SELECTOR 1 BIT 0
SELECTOR 1 BIT 1
SELECTOR 1 BIT 2
SELECTOR 1 STP ALARM
SELECTOR 1 BIT ALARM
SELECTOR 1 ALARM
SELECTOR 1 PWR ALARM
SELECTOR 2
ELEMENT:
SETTING GROUP ACT 1
↓
Setting Group
SETTING GROUP ACT 6
ELEMENT:
UNDERFREQ 1 PKP
Underfrequency
UNDERFREQ 1 OP
UNDERFREQ 1 DPO
UNDERFREQ 2 to 6
ELEMENT:
VOLT PER HERTZ 1 PKP
Volts per Hertz
VOLT PER HERTZ 1 OP
VOLT PER HERTZ 1 DPO
VOLT PER HERTZ 2
ELEMENT:
XFMR INST DIFF OP
Transformer
XFMR INST DIFF OP A
Instantaneous
XFMR INST DIFF OP B
Differential
XFMR INST DIFF OP C
ELEMENT:
XFMR PCNT DIFF PKP A
Transformer Percent
XFMR PCNT DIFF PKP B
Differential
XFMR PCNT DIFF PKP C
XFMR PCNT DIFF 2ND A
XFMR PCNT DIFF 2ND B
XFMR PCNT DIFF 2ND C
XFMR PCNT DIFF 5TH A
XFMR PCNT DIFF 5TH B
XFMR PCNT DIFF 5TH C
XFMR PCNT DIFF OP
XFMR PCNT DIFF OP A
XFMR PCNT DIFF OP B
XFMR PCNT DIFF OP C
FIXED OPERANDS
Off
On
INPUTS/OUTPUTS:
Cont Ip 1
Contact Inputs
Cont Ip 2
↓
Cont Ip 1
Cont Ip 2
↓
INPUTS/OUTPUTS:
Cont Op 1
Contact Outputs,
Cont Op 2
↓
Current
(from detector on
Cont Op 1
Form-A output only)
Cont Op 2
↓
INPUTS/OUTPUTS:
Cont Op 1
Contact Outputs,
Cont Op 2
↓
Voltage
(from detector on
Cont Op 1
Form-A output only)
Cont Op 2
↓
INPUTS/OUTPUTS
DIRECT INPUT 1 On
↓
Direct Inputs
DIRECT INPUT 32 On
GE Multilin
OPERAND DESCRIPTION
Selector Switch 1 is in Position Y (mutually exclusive operands).
First bit of the 3-bit word encoding position of Selector 1.
Second bit of the 3-bit word encoding position of Selector 1.
Third bit of the 3-bit word encoding position of Selector 1.
Position of Selector 1 has been pre-selected with the stepping up control
input but not acknowledged.
Position of Selector 1 has been pre-selected with the 3-bit control input but
not acknowledged.
Position of Selector 1 has been pre-selected but not acknowledged.
Position of Selector Switch 1 is undetermined when the relay powers up and
synchronizes to the 3-bit input.
Same set of operands as shown above for SELECTOR 1
Setting Group 1 is active
↓
Setting Group 6 is active
Underfrequency 1 has picked up
Underfrequency 1 has operated
Underfrequency 1 has dropped out
Same set of operands as shown for UNDERFREQ 1 above
V/Hz element 1 has picked up
V/Hz element 1 has operated
V/Hz element 1 has dropped out
Same set of operands as VOLT PER HERTZ 1 above
At least one phase of Transformer Instantaneous Differential has operated
Phase A of Transformer Instantaneous Differential has operated
Phase B of Transformer Instantaneous Differential has operated
Phase C of Transformer Instantaneous Differential has operated
Transformer Percent Differential protection has picked up in Phase A
Transformer Percent Differential protection has picked up in Phase B
Transformer Percent Differential protection has picked up in Phase C
The 2nd harmonic of Transformer Percent Differential has blocked Phase A
The 2nd harmonic of Transformer Percent Differential has blocked Phase B
The 2nd harmonic of Transformer Percent Differential has blocked Phase C
The 5th harmonic of Transformer Percent Differential has blocked Phase A
The 5th harmonic of Transformer Percent Differential has blocked Phase B
The 5th harmonic of Transformer Percent Differential has blocked Phase C
At least one phase of Transformer Percent Differential has operated
Phase A of Transformer Percent Differential has operated
Phase B of Transformer Percent Differential has operated
Phase C of Transformer Percent Differential has operated
Logic = 0. Does nothing and may be used as a delimiter in an equation list;
used as 'Disable' by other features.
Logic = 1. Can be used as a test setting.
On
(will not appear unless ordered)
On
(will not appear unless ordered)
↓
Off
(will not appear unless ordered)
Off
(will not appear unless ordered)
↓
IOn
(will not appear unless ordered)
IOn
(will not appear unless ordered)
↓
IOff
(will not appear unless ordered)
IOff
(will not appear unless ordered)
↓
VOn
(will not appear unless ordered)
VOn
(will not appear unless ordered)
↓
VOff
(will not appear unless ordered)
VOff
(will not appear unless ordered)
↓
Flag is set, logic=1
↓
Flag is set, logic=1
T60 Transformer Management Relay
5.4 FLEXLOGIC™
5
5-61