PROMPTS
Rpt Zn6 ONLY if
57
Armed (N)_
Enable Zn7 Y/N
58
(N)_
Zn7 Trigger Type
59
(V+)_
Invert Zn7 Y/N
60
(N)_
Restore Zn7 Y/N
61
(Y)_
Delay Zn7 (secs)
62
(00)_
Rpt Zn7 ONLY if
63
Armed (N)_
NOTE: The next two prompts (2 x 4204 Emulation Device Mode) are available ONLY when option "Tamper Rpt" is
DISABLED.
Restore Zn8 Y/N
64
(Y)_
Delay Zn8 (secs)
65
(00)_
Review? Y/N
66
4204/
ZONE
OPTIONS
2-4204
TRIG.
[Y], [N]
X
X
[Y], [N]
4204
only
• (EOLR)
X
4204
• (V+)
only
• (V–)
[Y], [N]
X
4204
only
[Y], [N]
X
X
[01-15]
X
X
[00] = no delay
[Y], [N]
X
[Y], [N]
2-
4204
only
[01-15]
2-
4204
[00] = no delay
only
[Y] = review
X
X
[N] = exit
Section 3: Programming the Communicator
DESCRIPTION
Reports alarms on zone 6 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 6.
Enables alarm reporting for zone 7, if used.
If [N], skip to Prompt 66: "Review."
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone 7
trigger; otherwise uses normal input signal.
Enables restore reporting for zone 7.
Zone Trigger mode: This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for
zone 7.
Zone Trigger mode: This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
UL/ULC: Must be set to "00."
Reports alarms on zone 7 ONLY if the conditional
zone (zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 7.
2-4204 mode: If any zone is programmed to "Report
Only if Armed," or if tamper is enabled, skip to
"Review."
Enables restore reporting for zone 8.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for
zone 8.
UL/ULC: Must be set to "00."
Reviewing Programming Mode Entries
To review the programming options (to ensure that
the correct entries have been made), press [Y]. The
programming questions are displayed again. Use
the up/down arrow keys to scroll through the
program fields without changing any of the values.
If a value requires change, simply type in the
correct value. When the last field is displayed, the
"REVIEW?" question again appears.
To exit the programming mode, press [N] in
response to the "REVIEW?" question, and refer to
Exiting Programming Mode below.