1 The CAT Display
The analyzer's large CRT displays data, markers, limit lines, Instrument BASIC IIBASICI
programming code, softkey menus and measurement parameters quickly and clearly. Refer tc
"Display' in Chapter 8 for more information.
The (BEGIN) key simplifies measurement setups. The begin key allows quick and easy
selection of basic measurement parameters for a user-specified class of devices [e.g., filters,
amplifiers, or mixers]. For example, when making a transmission measurement, selecting
Filter
measurement dynamic range. In comparison, selecting
analyzer into broadband detection mode, enabling frequency translation measurements. This
capability allows new users to start making measurements with as few as four keystrokes.
3 MEAS
The measure keys select the measurements for each channel. The analyzer's measurement
capabilities include transmission, reflection, power, conversion loss, and AM delay IOptions
4
The source keys select the desired source output signal to the device under test, for
SOURCE
example, selecting source frequenn/ range or output power. The source keys also control
sweep time, number of points, and sweep triggering.
The configure keys control receiver and display parameters. These parameters include
5 CONFIGURE
receiver bandwidth and averaging, display scaling and format, marker functions, and
instrument calibration.
6 SYSTEM
The system keys control system level functions. These include instrument preset, save/recall,
and hardcopy output. HP-W parameters and IBASIC are also controlled with these system
keys.
7 The Numeric Keypad
Use the number keys to enter a specific numeric value for a chosen parameter. Use the
You can also use the front panel knob for making continuous adjustments to parameter
values, while the @ and @ keys allow You to change values in steps.
these keys will be represented by the key name with a box around it
such as: (w).
9
displayed on the screen next to the 8 blank keys next to the display screen on the analyzer.
In text, these keys will be represented by the key name with shading behind it such as:
Sweep Time.
Tel:0755-83589391
as Your device type puts the analyzer into narrowband detection mode, maximizin
Fax:0755-83539691
Mixer
as Your device type puts tht
Website: www.Sengt.c