WARNING
Do not look into the reading aperture while a
scanning beam is being emitted.
Doing so can injure the eyes.
For Reference
A scanning beam stops in about one second if you
continue to press the trigger key but no bar code
is detected from the reading aperture.
If a bar code cannot be read, try changing the
direction of the scanning beam in relation to the
bar code or the distance of the IPAD from the
barcode.
Note that if the scanning beam passes over more
than one bar code, it cannot be determined which
of the bar codes will be read.
6.2

Bar Code Specifications

Item
PCS value
0.25 or more (Value for a 650 nm laser
Resolution
0.13 mm
Reading angle
Vertical direction: ± 65
Horizontal direction: ± 60
Rotation: ± 30
Reading depth
Narrow bar
width
0.13 mm
0.19 mm
0.25 mm
0.33 mm
0.51 mm
1.02 mm
1.40 mm
Reading
LED indication (green)
confirmed by:
* The minimum reading distance is determined by the bar code label width and the reading depth.
6.3
Cleaning the Reading Aperture of the Bar Code Scanner
The reading aperture of the bar code reader must always be clean when it is used.
Clean the reading aperture using a dry cloth or a cloth moistened with water or a diluted neutral detergent
solution. Do not use alcohol, thinner, or other volatile solvent.
Specifications
beam)
o
or less
o
or less
o
or less
Distance
5.6 to 12.7 cm
4.6 to 19.0 cm
5.08 to 24.6 cm
5.08 to 30.4 cm
* to 38.1 cm
* to 55.8 cm
* to 73.6 cm