Download Print this page
Mitsubishi Electric GT1155-QTBD Instructions Manual

Mitsubishi Electric GT1155-QTBD Instructions Manual

Hide thumbs Also See for GT1155-QTBD:

Advertisement

Quick Links

JY997D17401H
GT1155-QTBD, GT1155-QSBD, GT1150-QLBD
GT11 General Description
Manual Number
JY997D17401H
Date
Jul. 2008
This manual describes the part names, dimensions, mounting, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are
the registered trademarks or trademarks of each company.
Effective May 2008
Specifications are subject to change without notice.
©
2008 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before using.)
Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by "CAUTION" may also be
linked to serious results.
In any case, it is important to follow the directions for usage.
DESIGN PRECAUTIONS
• Some failures of the GOT or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
• If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
• Do not use the GOT as the warning device that may cause a serious
accident.
An independent and redundant hardware or mechanical interlock is required
to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
• Incorrect operation of the touch switch(s) may lead to a serious accident if the
GOT backlight is gone out.
When the GOT backlight goes out, the POWER LED flickers (green/orange)
and the display section turns black and causes the monitor screen to appear
blank, while the input of the touch switch(s) remains active.
This may confuse an operator in thinking that the GOT is in "screensaver"
mode, who then tries to release the GOT from this mode by touching the
display section, which may cause a touch switch to operate.
Note that the following occurs on the GOT when the backlight goes out.
- The POWER LED flickers (green/orange) and the monitor screen appears
blank
DESIGN PRECAUTIONS
• Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100mm (3.94in.) apart.Not doing so noise can cause a malfunction.
MOUNTING PRECAUTIONS
• Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the GOT to/from the panel.
Not doing so can cause the unit to fail or malfunction.
• When installing the battery, or operating the reset switch, wear an earth band etc.
to avoid the static electricity.
The static electricity can cause the unit to fail or malfunction.
MOUNTING PRECAUTIONS
• Use the GOT in the environment that satisfies the general specifications
described in this manual. Not doing so can cause an electric shock, fire,
malfunction or product damage or deterioration.
• When mounting the GOT to the control panel, tighten the mounting screws in the
specified torque range. Undertightening can cause the GOT to drop, short circuit
or malfunction. Overtightening can cause a drop, short circuit or malfunction due
to the damage of the screws or the GOT.
• When inserting/removing a CF card into/from the GOT, turn the CF card access
switch off in advance. Failure to do so may corrupt data within the CF card.
• When inserting a CF card into the GOT, push it into the insertion slot until the CF
card eject button will pop out. Failure to do so may cause a malfunction due to
poor contact.
• When removing a CF card from the GOT, make sure to support the CF card by
hand, as it may pop out. Failure to do so may cause the CF card to drop from the
GOT and break.
WIRING PRECAUTIONS
• Be sure to shut off all phases of the external power supply used by the system
before wiring. Failure to do so may result in an electric shock, product damage or
malfunctions.
• Please make sure to ground FG terminal of the GOT power supply section by
applying 100 or less which is used exclusively for the GOT. Not doing so may
cause an electric shock or malfunction.
• Correctly wire the GOT power supply section after confirming the rated voltage
and terminal arrangement of the product. Not doing so can cause a fire or failure.
• Tighten the terminal screws of the GOT power supply section in the specified
torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the
screws or the GOT.
• Exercise care to avoid foreign matter such as chips and wire offcuts entering the
GOT. Not doing so can cause a fire, failure or malfunction.
WIRING PRECAUTIONS
• Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction. Overtightening can
cause a short circuit or malfunction due to the damage of the screws or unit.
TEST OPERATION
PRECAUTIONS
• Before performing the test operations of the user creation monitor screen (such as
turning ON or OFF bit device, changing the word device current value, changing
the settings or current values of the timer or counter, and changing the buffer
memory current value), read through the manual carefully and make yourself
familiar with the operation method.
During test operation, never change the data of the devices which are used to
perform significant operation for the system. False output or malfunction can
cause an accident.
STARTUP/MAINTENANCE
PRECAUTIONS
• When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
• Connect the battery correctly. Do not discharge, disassemble, heat, short, solder
or throw the battery into the fire. Incorrect handling may cause the battery to
generate heat, burst or take fire, resulting in injuries or fires.
• Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can cause
a unit failure or malfunction. Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction due to the
damage of the screws or unit.
STARTUP/MAINTENANCE
PRECAUTIONS
• Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
• Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
• The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
• When unplugging the cable connected to the unit, do not hold and pull the cable
portion. Doing so can cause the unit or cable to be damaged or can cause a
malfunction due to a cable connection fault.
• Do not drop or apply any impact to the battery.If any impact has been applied,
discard the battery and never use it.
The battery may be damaged by the drop or impact.
• Before touching the unit, always touch grounded metal, etc. to discharge static
electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
Associated Manuals
The following manuals are relevant to this product. When these loose manuals are required, please consult with our local distributor.
Manual name
GOT1000 Series Extended/Option Function Manual
Describes extended functions and option functions applicable to GOT1000 series.
(sold separately)
*1
GOT1000 Series Connection Manual 1/3, 2/3, 3/3
Describes system configurations of the connection method applicable to GOT1000 series
(sold separately)
*1
and cable creation method
GT Designer2 Version2 Basic Operation/Data Transfer
Describes methods of the GT Designer2 installation operation, basic operation for drawing
Manual (For GOT1000 Series)
and transmitting data to GOT1000 series
(sold separately)
*1
GT Designer2 Version2 Screen Design Manual (For
GOT1000 Series) 1/3, 2/3, 3/3
Describes specifications and settings of the object functions used in GT Designer2
(sold separately)
*1
*1 Stored in the GT Works 2/GT Designer2 in PDF format.
For details of a PLC to be connected, refer to the PLC user's manual respectively.
Bundled Items
Product Name
Model Name
5.7" diagonal [320 × 240 dots], TFT color LCD (256 colors), built-in battery and backlight
GT1155-QTBD
5.7" diagonal [320 × 240 dots], STN color LCD (256 colors), built-in battery and backlight
GOT
GT1155-QSBD
5.7" diagonal [320 × 240 dots], STN monochrome LCD (black/white, 16 scales), built-in battery and backlight
GT1150-QLBD
Bundled item
Quantity
Mounting brackets
Mounting screws: M4 x 35mm (1.38")
1. Features
1) Improved monitoring performance and connectivity to FA devices
- Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts.
- Two types of display modes are provided: 256-color display and monochrome display.
In the monochrome display, 16 scales are used to improve the display.
- High-speed monitoring through high-speed serial communication at maximum tare of 115.2 kbps or through bus connection with the PLC.
- High speed display and high speed touch switch response.
2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works
- The 3MB user memory is included as standard.
- CF card interface is included as standard.
- The USB connector is positioned on the GOT front. This enables the system startup to be performed more efficiently using FA device setup tool, and eliminates the
indirect works (opening and closing the control panel, cable replacement, cable rewiring) in order to improve the working efficiency.
3) Enhanced support of FA setup tools
- PLC program transfer and monitoring are possible via the personal computer that is connected to the GOT if connected directly to the A, QnA, Q, or FX series of the PLC
CPU (FA transparent function).
DISPOSAL PRECAUTIONS
• When disposing of the product, handle it as industrial waste.
TRANSPORTATION
PRECAUTIONS
• When transporting lithium batteries, make sure to treat them based on the
transport regulations.
• Before transporting the GOT, turn the GOT power on and check that the battery
voltage status is normal on the Time setting & display screen (utilities screen). In
addition, confirm that the adequate battery life remains on the rating plate.
Transporting the GOT with the low battery voltage or the battery the reached
battery life may unstabilize the backup data unstable during transportation.
• Make sure to transport the GOT main unit and/or relevant unit(s) in the manner
they will not be exposed to the impact exceeding the impact resistance
described in the general specifications of this manual, as they are precision
devices. Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Contents
Specifications
Bundled item
4
Dust-/Water-proof packing
4
GT11 General Description (This manual)
Manual Number
(Model Code)
SH-080544ENG
(1D7M32)
SH-080532ENG
(1D7M26)
SH-080529ENG
(1D7M24)
SH-080530ENG
(1D7M25)
Quantity
1
1

Advertisement

loading

Summary of Contents for Mitsubishi Electric GT1155-QTBD

  • Page 1 GOT to/from the panel. Doing so can cause a failure, malfunction, injury or fire. Not doing so can cause the unit to fail or malfunction. GT1155-QTBD, GT1155-QSBD, GT1150-QLBD • Do not touch the conductive and electronic parts of the unit directly. TRANSPORTATION •...
  • Page 2: Power Led

    Displays the utility screen and the user creation screen. For communicating with controller (PLC, microcomputer Installation location Inside control panel GT1155-QTBD:320×240 dots, TFT color liquid crystal RS-232 board, bar code reader, RFID, etc) or personal computer Display screen GT1155-QSBD:320×240 dots, STN color liquid crystal...
  • Page 3: External Dimensions

    3.4 External Dimensions Specifications Item GT1155-QTBD GT1155-QSBD GT1150-QLBD 164(6.46") 120(4.73") Battery GT11-50BAT lithium battery (0.87") 23(0.91") Backup target Clock data, alarm history and recipe data Life Approx. 5 years (Operating ambient temperature of 25°C) RS422 1ch 1000 GRAPHIC OPERATION TERMINAL...
  • Page 4: Maintenance And Inspection

    (100Ω or less) (100Ω or less) illustration nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be the thinner side into the packing Retighten held responsible for any problems involving industrial property rights which may groove.
  • Page 5 Displays the utility screen and the user creation screen. For communicating with controller (PLC, microcomputer Installation location Inside control panel GT1155-QTBD:320×240 dots, TFT color liquid crystal RS-232 board, bar code reader, RFID, etc) or personal computer Display screen GT1155-QSBD:320×240 dots, STN color liquid crystal...
  • Page 6 (100Ω or less) (100Ω or less) illustration nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be the thinner side into the packing Retighten held responsible for any problems involving industrial property rights which may groove.

This manual is also suitable for:

Gt1155-qlbdGt1155-qsbd