Starting Self-Diagnostic Function; Starting Self-Diagnostic Function In The Protection Cancel Mode - Yamaha RX-V673 Service Manual

Hide thumbs Also See for RX-V673:
Table of Contents

Advertisement

RX-V673/HTR-6065/RX-A720
● Starting Self-Diagnostic Function
While pressing the "TONE CONTROL" and "INFO" keys, press the "MAIN ZONE
those 2 keys.
The self-diagnostic function mode is activated.
● Starting Self-Diagnostic Function in the protection cancel mode
If the protection function works and causes hindrance to troubleshooting, cancel the protection function by the procedure
below, and it will be possible to enter the self-diagnostic function mode. (The protection functions other than the excess
current detect function will be disabled.)
While pressing the "TONE CONTROL" and "INFO" keys, press the "MAIN ZONE " key to turn on the power and keep
pressing those 2 keys and "MAIN ZONE " key for 3 seconds or longer.
The self-diagnostic function mode is activated with the protection functions disabled.
In this mode, the "SLEEP" segment of the FL display flashes to indicate that the mode is self-diagnostic function mode with the
protection functions disabled.
CAUTION!
Using this unit with the protection function disabled may cause further damage to this unit. Use special care for this point
when using this mode.
30
Keys of this unit
RX-V673/HTR-6065
RX-A720
" key to turn on the power, and release
While pressing these keys, turn on the power.
While pressing these keys, turn on the power.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Htr-6065Rx-a720

Table of Contents