CHAPTER 14 ASYNCHRONOUS SERIAL INTERFACE (UART)
RXEn
Note
0
Disable reception
1
Enable reception
• Set the RXEn bit to 1 after setting the UARTEn bit to 1 at startup. Clear the UARTEn bit to 0 after clearing the
RXEn bit to 0 to stop.
• To initialize the reception unit status, clear (0) the RXEn bit, and after letting 2 Clock cycles (base clock) elapse,
set (1) the RXEn bit again. If the RXEn bit is not set again, initialization may not be successful. (For details about
the base clock, refer to 14.6.1 (1) Base clock.)
PSn1
PSn0
0
0
Don't output parity bit
0
1
Output 0 parity
1
0
Output odd parity
1
1
Output even parity
• To overwrite the PSn1 and PSn0 bits, first clear (0) the TXEn and RXEn bits.
• If "0 parity" is selected for reception, no parity judgment is performed. Therefore, no error interrupt is generated
because the ASISn.PEn bit is not set.
CLn
0
7 bits
1
8 bits
• To overwrite the CLn bit, first clear (0) the TXEn and RXEn bits.
SLn
0
1 bit
1
2 bits
• To overwrite the SLn bit, first clear (0) the TXEn bit.
• Since reception is always done with a stop bit length of 1, the SLn bit setting does not affect receive operations.
ISRMn
Enable/disable of generation of reception completion interrupt request signals when an error occurs
Generate a reception error interrupt request signal (INTSREn) as an interrupt when an error occurs.
0
In this case, no reception completion interrupt request signal (INTSRn) is generated.
1
Generate a reception completion interrupt request signal (INTSRn) as an interrupt when an error occurs.
In this case, no reception error interrupt request signal (INTSREn) is generated.
• To overwrite the ISRMn bit, first clear (0) the RXEn bit.
Note When reception is disabled, the receive shift register does not detect a start bit. No shift-in
processing or transfer processing to the RXBn register is performed, and the contents of the RXBn
register are retained.
When reception is enabled, the receive shift operation starts, synchronized with the detection of the
start bit, and when the reception of one frame is completed, the contents of the receive shift
register are transferred to the RXBn register. A reception completion interrupt request signal
(INTSRn) is also generated in synchronization with the transfer to the RXBn register.
Reception enable/disable
Transmit operation
Specification of character length of 1 frame of transmit/receive data
Specification of stop bit length of transmit data
User's Manual U16896EJ2V0UD
Receive operation
Receive with no parity
Receive as 0 parity
Judge as odd parity
Judge as even parity
(2/2)