Pioneer XDJ-RX Service Manual page 25

Dj system
Table of Contents

Advertisement

5
Trouble with the operating elements or LEDs
Direct-input keys
g
(EUP UCOM)
MIXB Assy: TAP, FX ON/OFF, BROWSE ENCODER, TIME ENCODER
CDJB Assy: CUE, PLAY/PAUSE, HOT CUE A, HOT CUE B, HOT CUE C,
HOT CUE D
PNL1 Assy: POWER SW
PNL2 Assy: MASTER REC
DPNL2 Assy: QUANTIZE
JOGT1/2 Assy: JOGT SW
JOGR Assy: JOGR A, JOGR B
Direct-input keys
(MAIN UCOM)
g
DPNL1 Assy: rekordbox, MIDI, USB1, USB2
DPNL2 Assy: DECK1/2, TIME MODE
JACK1 Assy: Phono1/Line1 SW
JACK2 Assy: Phono2/Line2 SW
Some of the matrix keys (SW) do not
function, and some of the LEDs cannot light.
No operation with keys (switches), No
operation with slide switches, No response
to pressing the rotary selector
The rotary VRs are inoperable.
The rotary selector is inoperable.
The JOG dial is inoperable.
5
6
Matrix keys
g
MIXB Assy: BROWSE, TAG LIST, INFO, MENU, NOISE, GATE/COMP, CRUSH,
CDJB Assy: LOOP IN, LOOP OUT, RELOOP, REV, SLIP, HOT CUE,
PNL1 Assy: USB1 STOP, MIC SELECT
PNL2 Assy: USB2 STOP, TRACK MARK
Direct-input A/Dkeys
g
MIXB Assy: COLOR1, COLOR2, CH1 FADER, CH2 FADER, CROSS FADER
g Multiplexer
MIXB Assy: TRIM1, TRIM2, HI1, HI2, MID1, MID2, LOW1, LOW2, HP MIXING,
CDJB Assy: TEMPO SLIDER, TOUCH/RELEASE
PNL1 Assy: MIC HI, MIC LOW
PNL2 Assy: BOOTH MONITOR, MASTER LEVEL
Check on the circuit diagram if the
inoperable keys and LEDs use the same grid.
Is the same grid used?
No
Only the direct-input keys
are inoperable.
No
Are the rotary VRs directly
connected to and controlled by
the microcomputers?
No
Check if a normal waveform is input to the microcomputer, referring to
"e
Jog rotation signal" in "10.46 WAVEFORMS."
If no problem is found, replace the microcomputer:
• Replace IC3601 in the MIXB Assy.
XDJ-RX
6
7
(EUP UCOM)
FILTER, HP CUE1, HP CUE2, LOAD1, LOAD2, BACK,
TAG TRACK/REMOVE, c BEATS, BEATS d, BROWSE PUSH,
INPUT1 SELECT, INPUT2 SELECT, CROSS FADER CURVE
AUTO BEAT LOOP, LOOP SLICE, SHIFT, VINYL, SYNC, MASTER,
MASTER TEMPO, TEMPO, c CALL, CALL d, DELITE, MEMORY,
o TRACK SEARCH, TRACK SEARCH p
(EUP UCOM)
A/Dkeys
(EUP UCOM)
HP LEVEL, LEVEL/DEPTH, BEAT EFFECT SW, BEAT CH SW
Check the corresponding grid, referring to
Grid control" in "10.46 WAVEFORMS." If no grid
waveform signal is output from the shift register
IC, check the communication line with the
microcomputer first, then check if the grid line is
short-circuited with GND, caused by a failure in
a key, LED, or the transistor for the drive. Also
Yes
check the connection of the grid line. If there is no
problem, replace the shift register IC:
• If the MIXER block is in failure
Replace IC3001 in the MIXB Assy.
• If the CDJ block is in failure
Replace IC4002 in the CDJB Assy.
• If the level meter LEDs do not light
Replace IC3501 in the LLED Assy.
See "No operation with keys (switches), No
operation with slide switches, No response
to pressing the rotary selector," or "The
LEDs do not light."
Check that current is conducted between the
terminals of the switch when it is pressed. If current
Yes
is not conducted, replace the switch. Check the line
between the switch and the microcomputer. If the
line is OK, replace the microcomputer to which the
switch is connected, as follows: MIXB Assy: IC3601.
Check the transistors on the line that is
connected to the microcomputer port and
waveforms and connections of the line. If no
problem is found, replace the microcomputer
(IC3601) in the MIXB Assy.
Check that the resistance value of the line that is
connected to ground and the microcomputer
changes in accordance with turning of the VR.
Yes
Check the connection line between the
microcomputer and the VR. If no problem is found,
replace the microcomputers to which the VR is
connected, as follows: MIXB Assy: IC3601.
Check that the resistance values of the lines that
are connected to GND and a microcomputer
change in response to turning of the VR.
Check the connection lines between the analog
SW ICs and rotary selectors/VRs, referring to
"f
A/D SW operations" in "10.46 WAVEFORMS."
If there is no problem, replace the analog SW IC to
which an inoperable rotary selector/VR is connected:
• If the MIXER block is in failure
Replace IC3201 and IC3202 in the MIXB Assy.
• If the CDJ block is in failure
Replace IC4001 in the CDJB Assy.
7
8
A
B
"5
C
D
E
F
25
8

Hide quick links: