The I/O Connector; Battery; Replacement Battery Specifications - Honeywell Dolphin 75e User Manual

Hide thumbs Also See for Dolphin 75e:
Table of Contents

Advertisement

Preliminary Draft, Not for Release - Please Review 2-3-2015
Power Button
The Power button
button is pressed.
• A quick press of the button toggles
• Press and hold the button down for approximately 4 seconds to access the Options menu to Power Off the terminal,
Reboot (Hard Reset) the terminal, enable Airplane Mode, set the Volume of the active speaker to On, Off, or Vibrate.
To modify this feature, see
• Press and hold the button down for approximately 8 seconds to initiate a manual Reboot (Soft Reset) if the touch screen
has stopped responding.
Volume Control Button
Press the top or bottom of the volume button to raise or lower the volume of the active speaker. Lower the volume all the
way down to turn off the volume and enable vibration mode.

The I/O Connector

The I/O connector powers the terminal, charges the main battery, and facilitates communication. Dolphin 75e peripherals are
designed to work exclusively with this connector. The I/O connector supports low, full, and high speed USB v2.0 communication
with a maximum rate of 480 Mbps.
Pin
Signal
1
VDC_IN
2
VBUS_HOST
3
USB_DM_HOST
4
USB_DP_HOST
5
USBC_DET
6
GND
7
USB_DN_DOCK
8
USB_DP_DOCK
9
VBUS_DOCK
Note: Signals referenced are for a DTE device.

Battery

The primary power source for the Dolphin terminal is the 3.7V Li-ion rechargeable battery located under the battery door on the
back panel of the device. Honeywell recommends, you keep the battery in the terminal charged at all times to help prevent data
loss. Letting the battery become fully discharged causes the terminal to lose all data in RAM.
Note: All data in RAM is cleared when the battery is removed. Always power off the terminal before removing the battery to
ensure any changes made are saved to the flash memory.

Replacement Battery Specifications

Dolphin 75e model terminals are designed for use with battery part numbers BAT-STANDARD-02 (Li-ion 3.7V, 6.179 watt
hour) and BAT-EXTENDED-02 (Li-ion 3.7V, 12.358 watt hour) manufactured for Honeywell International Inc. See page
for battery replacement instructions.
3 - 8
located on the top of the terminal initiates multiple functions depending on the length of time the
Suspend Mode
Show System Dialog
Description
5V DC input for charging and operation
5V output for USB host and peripheral power
USB D- for the host port
USB D+ for the host port
Multipurpose pin to allow for detection of an
unpowered SLED, determine SLED type, and to
signal a HomeBase the docking of the terminal.
Ground connection
USB D- for the client port
USB D+ for the client port
5V input for USB client (and charging)
On or Off. To modify this feature, see
on page
6-2.
Power Key
on page
6-2.
Terminal Back Panel
Pin 9
Pin 1
2-10

Advertisement

Table of Contents
loading

Table of Contents