To Examine Software Execution When A Timing Violation Occurs - HP 16500B User Manual

Logic analysis system
Hide thumbs Also See for 16500B:
Table of Contents

Advertisement

To examine software execution when a timing
violation occurs
The timing analyzer triggers when the timing violation occurs, and when it
triggers, it also sets its "arm" level to true. When the state analyzer receives
the arm signal, it triggers immediately on the present state.
Select the timing analyzer Trigger menu.
1
Define the Edge1 term to represent the control line where the timing
2
violation occurs.
Under Timing Sequence Levels, enter the following sequence
3
specification:
TRIGGER on "glitch/edge1" 1 time
Select the state analyzer Trigger menu and accept the default
4
(anystate) definition for term a.
Under State Sequence Levels, enter the following sequence
5
specification:
While storing "anystate" TRIGGER on "arm • a" 1 time
Store "anystate"
To examine software execution when a timing violation occu
Triggering
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

16501a

Table of Contents