Weight and physical dimensions
nl
Table 12 (page 33)
Table 12 16Gb SAN Switch physical dimensions
Dimension
Height
Width
Depth
Weight
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in
environment for both operating and nonoperating conditions.
Table 13 Environmental requirements
Condition
Ambient
temperature
Humidity
Altitude
Shock
Vibration
Supported SFPs
Do not use unsupported SFPs. They may not fit correctly and may void your warranty. Any port
with an unsupported SFP will automatically be disabled by switch firmware, leaving the port
non-operational. See
For a complete list of supported devices, see the latest version of the HP SAN Design Reference
Guide at the HP website:
nl
http://h18000.www1.hp.com/products/storageworks/san/documentation.html.
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches, see the
latest version of the HP SAN Design Reference Guide at the HP website:
nl
http://h18000.www1.hp.com/products/storageworks/san/documentation.html.
lists physical properties.
Measurement
27.94 mm (1.1 in)
192.84 mm (7.59 in)
269.46 mm (10.6 in)
1.49 kg (3.3 lb) without media
Acceptable range during operation
10° to 35°C (50° to 95°F) at sea level
with an altitude derating of 1.0°C per
every 305m (1.8°F per every 1000ft)
above sea level to a maximum of 3050m
(10,000ft), no direct sustained sunlight.
Maximum rate of change is 10°C/Hr
(18°F/Hr ). The upper limit may be limited
by the type and number of options
installed. System performance may be
reduced if operating with a fan fault or
above 30°C (86°F).
10% to 90% relative humidity,
non-condensing
0 to 10,000 ft (3 km) above sea level
40 G, 2ms duration
1 G, 10–500 Hz
Supported SFP transceiver options (page 8)
Table 13 (page 33)
list the acceptable
Acceptable range during non-operation
Non-operating -30° to 60°C (-22° to
140°F). Maximum rate of change is
20°C/Hr (36°F/Hr).
5% to 95% relative humidity,
non-condensing
0 to 30,000 ft (9144 m) above sea
level
140 G, 2ms
2.0 G, 5–500 Hz
for a list of supported SFPs.
Weight and physical dimensions
33