HP 3600 v2 series Configuration Manual page 121

Hide thumbs Also See for 3600 v2 series:
Table of Contents

Advertisement

Configuration procedure
Configure PE 1.
1.
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE1> system-view
[PE1] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure Ethernet 1/0/1 as a trunk port and assign it to all VLANs.
[PE1] interface ethernet 1/0/1
[PE1-Ethernet1/0/1] port link-type trunk
[PE1-Ethernet1/0/1] port trunk permit vlan all
# Disable STP on Ethernet 1/0/1, and then enable BPDU tunneling for STP and PVST on it.
[PE1-Ethernet1/0/1] undo stp enable
[PE1-Ethernet1/0/1] bpdu-tunnel dot1q stp
[PE1-Ethernet1/0/1] bpdu-tunnel dot1q pvst
Configure PE 2.
2.
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE2> system-view
[PE2] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure Ethernet 1/0/2 as a trunk port and assign it to all VLANs.
[PE2] interface ethernet 1/0/2
[PE2-Ethernet1/0/2] port link-type trunk
[PE2-Ethernet1/0/2] port trunk permit vlan all
# Disable STP on Ethernet 1/0/2, and then enable BPDU tunneling for STP and PVST on it.
[PE2-Ethernet1/0/2] undo stp enable
[PE2-Ethernet1/0/2] bpdu-tunnel dot1q stp
[PE2-Ethernet1/0/2] bpdu-tunnel dot1q pvst
113

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents