Download  Print this page

List Of Remote Buffer Memory - Mitsubishi Electric NZ2GF12A4-16D User Manual

Cc-link ie field network waterproof/dustproof remote i/o module.
Hide thumbs

Advertisement

3.6

List of Remote Buffer Memory

This section lists the remote buffer memory areas of the I/O module.
The remote buffer memory areas of the I/O module are assigned as shown below.
Description of a remote buffer memory area
■I/O response time setting (address: 0000H)
The following shows the description of I/O response time setting (address: 0000H) as an example.
Item
I/O response time setting
(address: 0000H)
■Input OFF delay setting X (address: 0110H to 012FH)
The following shows the description of Input OFF delay setting X (address: 0110H to 012FH) as an example.
Item
Input OFF delay setting
X
(address: 0110H to 012FH)
For details on the remote buffer memory, refer to the following.
Page 154 Details of Remote Buffer Memory Addresses
: Available, : Not available
Address
Decimal
Hexadecimal
0 to 255
0000H to 00FFH
256 to 511
0100H to 01FFH
512 to 767
0200H to 02FFH
768 to 1023
0300H to 03FFH
1024 to 1279
0400H to 04FFH
1280 to 1535
0500H to 05FFH
1536 to 1791
0600H to 06FFH
1792 to 2047
0700H to 07FFH
2048 to 2303
0800H to 08FFH
2304 to 2559
0900H to 09FFH
2560 to 4095
0A00H to 0FFFH
4096 to 4351
1000H to 10FFH
4352 to 4607
1100H to 11FFH
4608 to 4863
1200H to 12FFH
4864 to 5119
1300H to 13FFH
5120 to 5375
1400H to 14FFH
*1 For the REMFR and REMTO instructions, refer to the following.
 User's manual for the master/local module used
*2 For the access method, refer to the following.
Parameter area ( Page 72 Parameter Setting)
Error history area ( Page 121 Checking for the Error Codes and the Warning Codes)
3 SPECIFICATIONS
3.6 List of Remote Buffer Memory
Description
Setting item
Remote buffer memory address
Description
Setting item
Input signal or output signal
Remote buffer memory address
Area
Target
Parameter area
Station-based parameter data
Module-based
parameter
data
Monitoring area
Station-based monitor data
Module-based
monitor data
Error history area
Station-based error history data
Module control data
Station-based control data
area
Module-based
control data
Access method
CC IE Field
configuration of
the engineering
tool
*2
I/O module
System area
System area
System area
I/O module
System area
System area
System area
*2
I/O module
System area
System area
System area
REMFR
instruction,
REMTO
*1
instruction

Advertisement