Troubleshooting Chart - Maytag ATB1821AR series Service Manual

Amana,magic chef 18 & 21 cubic foot top mount refrigerators
Table of Contents

Advertisement

Troubleshooting Chart

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Symptom
Frost or ice on evaporator
Unit starts and stops frequently
(cycles on and off)
16025860
!
WARNING
Possible Causes
Defrost thermostat faulty
Evaporator fan faulty
Defrost heater remains open
Fusible link
Defrost control faulty
Open wire or connector
Refrigerant shortage or restriction
Loose wire or thermostat
connections
Supply voltage out of specification
Overload protector open
Faulty compressor motor capacitor
(some compressors do not require
motor capacitor)
Faulty fan motor
Restricted air flow
Refrigerant shortage or restriction
22
Corrective Action
Check defrost thermostat. Replace if
failed.
Check fan motor. Replace if failed.
Check defrost heater continuity.
Replace if failed
Check control and replace if failed.
Check wiring and connections.
Repair as necessary.
Check for leak or restriction. Repair,
evacuate and recharge system.
Check wiring and connections.
Repair as necessary.
Check input voltage. Correct any
supply problems.
Check overload protector for
continuity. If open, replace overload.
NOTE: Ensure
overload/compressor are below
trip temperature before testing.
Check capacitor for open/short.
Replace if necessary.
NOTE: Discharge capacitor
before testing.
Check fan motor. Replace if failed.
Check condenser and grille for dirt.
Clean.
Check for leak or restriction. Repair,
evacuate and recharge system.
©2005 Maytag Services