Classification
Name
Output axis
Output axis
module
Cam data
Classification
Name
Cam data
Cam data
3 SYNCHRONOUS CONTROL MODULE
28
3.1 List of Synchronous Control Module
Parts
Function description
The cam conversion is processed
based on the input travel value and the
setting cam data. The current feed
value is output as the command to the
servo amplifier.
Function description
It controls the operation pattern of the output axis (two-
way operation and feed operation), which is
corresponding to the input travel value of the output axis
module.
Maximum number of usable
Number per module
R32MTCPU
R16MTCPU
32
16
Maximum number of usable
Number per module
Up to 1024
Reference
Number
per axis
Page 113
1
Output Axis
Module
Reference
Page 73
CAM
FUNCTION