7.4

Synchronous Control Initial Position

The following synchronous control monitor data can be aligned to a set position when starting synchronous control, as the
initial position for synchronous control.
The alignment to a synchronous control initial position is useful for restoring a system based on the last control status along
with restarting synchronous control after cancelling midway.
Synchronous control monitor data
[Md.400] Current value after composite main shaft gear (D13600+30n,
D13601+30n)
[Md.401] Current value per cycle after main shaft gear (D13602+30n,
D13603+30n)
[Md.402] Current value per cycle after auxiliary shaft gear (D13604+30n,
D13605+30n)
[Md.407] Cam axis current value per cycle (D13612+30n, D13613+30n)
[Md.408] Cam reference position (D13614+30n, D13615+30n)
[Md.409] Cam axis current feed value (D13616+30n, D13617+30n)
[Md.400] Current value after composite main shaft gear
(D13600+30n, D13601+30n)
Composite
Main shaft
main shaft
main input axis
gear
Main shaft
sub input axis
Auxiliary shaft
Auxiliary shaft
gear
clutch
Auxiliary
shaft axis
[Md.402] Current value per cycle after auxiliary
shaft gear (D13604+30n, D13605+30n)
[Pr.461] Setting method of current value per cycle
after auxiliary shaft gear (D15101+150n)
0: Previous value
1: Initial setting value of current value per
2: Calculate from input axis
Main shaft
gear
[Md.401] Current value per cycle after main shaft gear
(D13602+30n, D13603+30n)
Main shaft
clutch
Composite auxiliary
shaft gear
[Md.407] Cam axis current
value per cycle
(D13612+30n, D13613+30n)
Output axis
[Md.408] Cam reference position
(D13614+30n, D13615+30n)
[Md.409] Cam axis current feed
value
(D13616+30n, D13617+30n)
cycle after auxiliary shaft gear
The position when starting synchronous control
Restored to a position based on the main input axis of the main shaft.
Restored according to "[Pr.460] Setting method of current value per cycle after
main shaft gear (D15100+150n)".
Restored according to "[Pr.461] Setting method of current value per cycle after
auxiliary shaft gear (D15101+150n)".
Restored according to "[Pr.462] Cam axis position restoration object
(D15102+150n)".
[Prr.460] Setting method of current value per
cycle after main shaft gear (D15100+150n)
0: Previous value
1: Initial setting value of current value per
cycle after main shaft gear
2: Calculate from input axis
[Pr.462] Cam axis position
restoration object (D15102+150n)
0: Cam axis current value per
cycle restoration
1: Cam reference position
restoration
2: Cam axis current feed value
restoration
7 AUXILIARY AND APPLIED FUNCTIONS