Honeywell LYNXR Installation And Setup Gude page 21

Ademco lynxr series
Hide thumbs Also See for LYNXR:
Table of Contents

Advertisement

SYSTEM STATUS REPORT CODES (
Exit Error Report Code
59
6HH QRWHV DERYH
Trouble Report Code
60
6HH QRWHV DERYH
Bypass Report Code
61
6HH QRWHV DERYH
AC Loss Report Code
62
6HH QRWHV DERYH
Low Battery Report Code
63
6HH QRWHV DERYH
Test Report Code
64
6HH QRWHV DERYH
Open Report Code
65
6HH QRWHV DERYH
Arm AWAY/STAY Report Code
66
6HH QRWHV DERYH
RF transmitter Low Batt. Report Code
67
6HH QRWHV DERYH
Cancel Report Code
68
6HH QRWHV DERYH
RESTORE REPORT CODES (✻70–✻76)
Alarm Restore Report Code, 1st Digit
70
6HH QRWHV DERYH
Trouble Restore Report Code
71
6HH QRWHV DERYH
Bypass Restore Report Code
72
6HH QRWHV DERYH
AC Restore Report Code
73
6HH QRWHV DERYH
Low Battery Restore Report Code
74
6HH QRWHV DERYH
Data Field Descriptions
59–
68)
If the system is armed and an entry/exit or interior zone is still open
after the exit delay time has expired, an alarm will sound at the
keypad and external sounder. If the system is disarmed before the
end of the entry delay that immediately follows, the alarm sounding
will stop and no message will be sent to the central station. The
keypad will display "CA (CANCELED ALARM)."
If the system is not disarmed before the end of the entry delay
mentioned above, and an entry/exit or interior zone is still open, an
"exit alarm" message will be sent to the central station if an Exit
Error report code is selected in this field. The keypad will display
"EA (EXIT ALARM)," and the alarm sounding will continue until
the system is disarmed (or timeout occurs).
An Exit Alarm condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay,
and an "Exit Alarm" message will be sent to the central station.
If Contact ID® format has been programmed, the message will
contain the zone number and error code 374 (Trouble–Exit Error). If
4+2 format is used, the digit entered in this field will be sent
followed by the second digit of the programmed alarm code for that
zone. If 3+1 or 4+1 format is used, only the digit entered in this field
will be sent. This message will go to the primary phone no. Under
any of these conditions, no restore message will be sent.
If "0" is entered in this field, no special message will be sent, only
the regular alarm and alarm restore code for the zone.
This will be sent if a zone goes into trouble.
This will be sent when a zone is manually bypassed.
Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no AC restore report.
This will be sent when a low battery condition exists in the system's
standby battery.
This is sent periodically to test that the communicator and phone
lines are operational (frequency of report is selected in field ✻51).
This is sent upon disarming of the system. 2nd digit = user number,
if expanded or 4+2 reporting is selected.
This option allows for independent programming of AWAY and
STAY reports. 2nd digit of report is user number if expanded or 4+2
reporting is selected.
NOTE: OPEN reports are not sent if the associated closing report is
not enabled.
This is sent in the event that a wireless transmitter low battery
condition exists.
This is sent upon disarming of the system after an alarm condition
was reported.
Sent when the zone that caused an alarm is restored to its non-
faulted condition. 2nd digit is automatically sent as the 2nd digit of
the zone alarm report code programmed in field ✻56, if expanded or
4+2 reporting is selected.
Sent when a trouble in a zone is restored.
Sent when a zone that has been bypassed is unbypassed.
Sent when AC power has been restored after an AC power outage.
Sent when a system low battery condition is restored to normal.
–21–