Zone Response Type Definitions
Auxiliary Alarm
Supervised
5806/5807/5808
01000-020-V0
Interior w/Delay
Arm–Away
No Alarm Response
Silent Burglary
Type 07
Zone type 07 is usually assigned to a zone containing an Emergency
24-hour
button (audible emergency).
Audible
Zone Characteristics:
Alarm
• Sends a report to the central station, and provides alarm sounds
externally and at the keypad.
Zone type 08 is usually assigned to a zone containing a button for use
Type 08
in personal emergencies or to a zone containing monitoring devices
24-hour
(i.e.: water or temperature sensors, etc.).
Zone Characteristics:
• Sends a report to the central station and provides an alarm sound at
the keypad. (No bell output is provided and there is no keypad
timeout.)
Zone type 09 can be assigned to any wireless zone used as a
Type 09
fire zone. This zone type is always active and cannot be
bypassed.
Fire
Zone Characteristics:
• Bell output will pulse when this zone type is alarmed.
Zone type 10 is bypassed when the panel is armed in the STAY or STAY
Type 10
NO DELAY mode.
Zone Characteristics:
• Entry delay #1 (with programmed entry time) when armed in the
AWAY mode.
• Entry delay begins whenever sensors in this zone are violated,
regardless of whether an entry/exit delay zone was tripped first.
• No entry delay when armed in the AWAY NO DELAY mode.
• Exit delay regardless of the arming mode selected.
Zone type 20 is a special-purpose zone type used with 5800 Series
Type 20
wireless pushbutton units.
Arm–Stay
Zone Characteristics:
• Exit delay regardless of the arming mode selected.
• System is armed in the STAY mode when the zone is activated.
• Zone number is sent to the central station as a user number when
arming or disarming.
Zone type 21 is a special-purpose zone type used with 5800 Series
Type 21
wireless pushbutton units.
Zone Characteristics:
• System is armed in the AWAY mode when the zone is activated.
• Zone number is sent to the central station as a user number when
arming or disarming.
Zone type 22 is a special-purpose zone type used with 5800 series
Type 22
wireless pushbutton.
Disarm
Zone Characteristics:
• Disarms the system when the zone is activated.
Zone type 23 can be used on a zone when a Powerline Carrier Device
Type 23
(e.g., X-10) action is desired, but with no accompanying alarm (e.g.,
front door light).
Zone type 24 is usually assigned sensors or contacts on exterior doors
Type 24
and windows where bells and/or sirens are NOT desired.
Zone Characteristics:
• Instant alarm, with NO audible indication when is armed in the
AWAY, STAY, STAY NO DELAY, or AWAY NO DELAY mode.
• Report sent to the central station.
Note: Keypad beeps if the zone is faulted when system is disarmed and Chime
mode is on.
–16–