Power Controls; Power Switch; Power Button; Power Configuration - Honeywell Thor VM2 User Manual

Hide thumbs Also See for Thor VM2:
Table of Contents

Advertisement

Power Controls

Power Switch

Power Button

Power Configuration

Use the
Power Options
For information on the Ignition input signal see
Control Wiring Diagram
AC/DC
The Thor VM2 is powered on manually. When external power is present, the "Plugged In" power management tim-
eouts are used,
Ignition Control
The Thor VM2 is configured to power on when the vehicle ignition is switched on. When either Ignition Control/
Ignition On or Ignition Control/Ignition Off is selected and external power is present, the Thor VM2 uses the
"Pugged In" power management plan/scheme settings which corresponds to the state of the vehicle ignition.
Auto-On
The Thor VM2 is designed to power on whenever external power is present. When external power is present, the
"Plugged In" power management timeouts are used.
After all cables are connected, the Thor VM2 can be powered on.
There is a power switch located on the back of the dock. The power switch is a rocker
switch.
The power switch has a raised bump to identify the switch position even when it is hidden
from view. When the side of the switch with the raised bump is pressed, the power switch
is On. If the dock is connected to external power, the dock delivers power to the Thor VM2.
Generally, once the dock is powered On, there is no need to power it off. The dock power
can remain On even when the Thor VM2 is not attached.
The power button is located at the lower left of the Thor VM2.
If the Thor VM2 is Off, pressing the power button starts the power up
sequence.
Note: This assumes that the Thor VM2 is docked in a powered dock
If the Thor VM2 is On, pressing the power button performs the option
selected in the Advanced tab of the Power control panel (options may
vary by OS type):
• Ignore power button press
• Prompt the user to select action
• Shut down (default, an orderly shutdown is performed)
• Standby/Sleep
• Hibernate
(page 5-20) control panel to select the desired power scheme/plan.
Vehicle 10-60VDC Direct Power Connection
(page 4-22).
or that the internal UPS battery has a sufficient charge to
power the Thor VM2. If no external power is available and the
UPS battery does not have a charge, pressing the power
button causes no action.
(page 4-20) and
Auto-On
3 - 5

Advertisement