UPS
When the Thor VM2 is operating on the UPS the timeouts from the battery section for the selected power scheme/
plan are used. By default, the timeouts for UPS are the same for each power scheme/plan.
UPS Behavior
The Thor VM2 behavior when operating from UPS power is described below.
Thor VM2 is Off
Conditions
The Thor VM2 is Off and the power button is pressed the Thor VM2 and both the following conditions are
met:
• UPS power is over 10% capacity
• CPU temperature is over 20ºC
Result
The Thor VM2 boots and follows the selected power scheme's Running on Batteries (or power plan's On
battery) timeouts with power management timers reset at boot up.
Conditions
The Thor VM2 is Off and the power button is pressed the Thor VM2 and at least one of the following con-
ditions are met:
• UPS power is under 10% capacity
• CPU temperature is under 20ºC
Results
The Thor VM2 remains Off.
Thor VM2 is On
Conditions
The Thor VM2 is On and external power is removed, such as:
• Thor VM2 is removed from a powered dock (Dock power switch On)
• Thor VM2 is mounted to a dock and truck power is removed from the dock
• Thor VM2 is mounted to a dock and the dock power switch is turned Off
Result
The Thor VM2 boots and follows the selected power scheme's Running on Batteries (or power plan's On
battery) timeouts with power management timers reset at the time of power removal. UPS charging is
disabled.