Note: A non-zero HPR message rate should be chosen for View \ Interface to be active. The compass rose showing
Heading ant Tilt information will require a fast processor (Pentium) to respond fast enough with the compass output.
Slower computers will result in large time lags between the compass output and the display. All selected NMEA
messages will be updated in the Display \ Monitor NMEA Sentences
The HMR3000 output can be changed to include all or any of the six NMEA sentences each with its own rate.
User can capture the output messages to a file using the Capture Mode by selecting the message to be captured.
[Diagnostics \ Options menu]. User can also change the measurement parameters of the HMR3000 through PC Demo
Interface software.
2.8
Configuring the HMR3000
Following is a list of basic parameters that would be accessed routinely and at installation. Advanced parameters that
control the operation of the magnetometer, heading output, and warning levels are described in the Configuration
Parameters section
2.9

Using PC Demo Interface

Activate the Tune Parameters button to configure.
Function
Parameter /Description
Declination
Declination
Angle between magnetic north and
geographic north. Add declination to
magnetic heading to obtain True heading
Output
HDG, HDT, XDR, HPR, RCD, CCD
Messages and
NMEA sentence outputs
Rate
Rates in sentences per minute
Data Filter
TC1
Time constant for IIR filter
Heading Output
L and S
Smoothing factors for non linear filter
Deviation
Deviation
The angle between compass forward direction
and that of the platform.
Add deviation to get platform heading
2.10
Communication—RS485 Option
Operation and configuration of a HMR3000 with RS485 interface is directed through direct command input from the host
computer/microprocessor. No graphical interface is supplied with this product option. See Configuration Parameters section
for details and Figure 2 for computer connections.
TD
RD
GD
Table 2. Parameters attached routinely or at installation
RS-232 to RS-485
B & B Electronics
#485TBLED
SD Con trol
Shield
Echo Off
TD(A)
RS-232
TD(B)
2 RD
RD(A)
3 TD
RD(B)
7 GD
GND
+12V
+12VDC
VAC
900240 Rev. B
Located under
General page
Serial Output page
General page
RS -485
1
2
(B)
2
3
(A)
3
4
5
Gnd
5
6
Pwr
9
7
DB9 socket
connector
3/01
Range
±
0-180 deg
±
0- 3200 mils
None or All
0-1200 /min
0-255
1=72 ms
0<S<1
L= integer >1
L=0 disable
L<256
±
0-180 deg
±
0- 3200 mils
RS -485
Gnd
+12 VDC
page 4