8.2 Electrical Connection
The wires in the mains lead are coloured in
accordance with the following code:
• A - green and yellow: Earth
• C - brown: Live
• D - blue: Neutral
As the colours of the wires in the mains
lead of this appliance may not correspond
with the coloured markings identifying the
terminals in your plug, proceed as follows:
1. Connect the wire coloured green and
yellow to the terminal marked either
with the letter "E" or by the earth

9. NOISES

There are some sounds during normal running (compressor, refrigerant circulation).
CAUTION!
Any electrical work required
to install this appliance should
be carried out by a qualified
electrician or competent
person.
WARNING!
This appliance must be
earthed.
The manufacturer declines
any liability should these
safety measures not be
observed.
A
B
symbol
yellow.
2. Connect the wire coloured blue to the
terminal either marked with the letter
"N" or coloured black.
3. Connect the wire coloured brown to
the terminal either marked with the
"L" or coloured red.
4. Check that no cut, or stray strands of
wire is present and the cord clamp (E)
is secure over the outer sheath.
Make sure the electricity supply
voltage is the same as that indicated
on the appliance rating plate.
5. Switch on the appliance.
The appliance is supplied with a 13 amp
fuse (B). In the event of having to change
the fuse in the plug supplied, a 13 amp
ASTA approved (BS 1362) fuse must be
used.
WARNING!
A cut off plug inserted into a
13 amp socket is a serious
safety (shock) hazard. Ensure
that it is disposed of safely.
8.3 Ventilation requirements
C
The airflow behind the appliance must be
D
sufficient.
E
5 cm
CAUTION!
Refer to the assembly
instructions for the
installation.